Component based Automation<br />

Controller / Distributed I/O for PROFIBUS<br />

■ Technical specifications (continued) ■ Ordering data Order No.<br />

MPI mode<br />

Number of connections (also with<br />

DP master module plugged in)<br />

Utilities<br />

12 (per CPU)<br />

PG/OP communication Yes<br />

Routing Yes (with master module)<br />

Global data communication Yes<br />

S7 standard communication Yes<br />

S7 communication Yes<br />

- As a server Yes<br />

- As a client No<br />

Transmission rates<br />

DP slave mode<br />

Max. 12 Mbit/s<br />

Number of connections<br />

Utilities<br />

12 (per CPU)<br />

PG/OP communication Yes<br />

Routing Yes (only with active interface<br />

and with master mode)<br />

Global data communication No<br />

S7 standard communication No<br />

S7 communication No<br />

Transmission rate Up to 12 Mbit/s<br />

Transfer memory 244 Byte I/244 Byte O<br />

Address area, max. 32 with max. 32 byte each<br />

DPV1<br />

2nd interface<br />

No<br />

Type External interface over master<br />

module 6ES7 138-4HA00-0AB0<br />

Physical characteristics RS 485<br />

Isolated Yes<br />

Power supply on interface<br />

(DC 15 to 30 V), max.<br />

Functionality<br />

None<br />

MPI No<br />

PROFIBUS DP Yes, DP-Master<br />

Point-to-point coupling No<br />

Number of connections<br />

Utilities<br />

12 (per CPU)<br />

PG/OP communication Yes<br />

Routing Yes<br />

Global data communication No<br />

S7 standard communication No<br />

S7 communication Yes (server only)<br />

Direct data exchange Yes<br />

Isochronicity Yes<br />

Sync/Freeze Yes<br />

Activate/disable DP slaves Yes<br />

DPV1 Yes<br />

Transmission rates Up to 12 Mbaud<br />

Number of DP slaves per station 32<br />

Address area, max. 2 Kbyte I / 2 Kbyte O<br />

Useful data per DP slave Max. 244 byte I /244 byte O<br />

IM 151-7 CPU interface modules<br />

Interface module IM 151/CPU 6ES7 151-7AA10-0AB0<br />

(48 K)<br />

Including termination module<br />

Interface module IM 151/CPU FO 6ES7 151-7AB00-0AB0<br />

(48 K)<br />

Including termination module<br />

Accessories<br />

MMC 64 KB 1) 6ES7 953-8LF11-0AA0<br />

For program backup<br />

MMC 128 KB 1) 6ES7 953-8LG11-0AA0<br />

For program backup<br />

MMC 512 KB 1) 6ES7 953-8LJ11-0AA0<br />

For program backup<br />

MMC 2 MB 1) 6ES7 953-8LL11-0AA0<br />

For program backup and/or<br />

firmware update<br />

MMC 4 MB 1) 6ES7 953-8LM11-0AA0<br />

For program backup<br />

MMC 8 MB 1) 6ES7 953-8LP11-0AA0<br />

For program backup<br />

MMC adapter 6ES7 798-0BA00-0AA0<br />

For PG memory card slot<br />

External PROM programmer 6ES7 792-0AA00-0XA0<br />

For e.g. MMC with USB interface<br />

PG On request<br />

with integral MMC interface<br />

DIN A4 sheets of labels<br />

Petrol 6ES7 193-4BH00-0AA0<br />

Red 6ES7 193-4BD00-0AA0<br />

Yellow 6ES7 193-4BB00-0AA0<br />

Light beige 6ES7 193-4BA00-0AA0<br />

Manual for ET 200S<br />

German 6ES7 151-1AB00-8AA0<br />

English 6ES7 151-1AB00-8BA0<br />

Terminating module 6ES7 193-4JA00-0AA0<br />

For ET 200S<br />

<strong>SIMATIC</strong> S5, standard DIN rail 6ES5 710-8MA11<br />

35 mm, length 483 mm<br />

for 19“ cabinets<br />

<strong>SIMATIC</strong> S5, standard DIN rail<br />

35 mm, length 530 mm<br />

for 600 mm cabinets<br />

<strong>SIMATIC</strong> S5, standard DIN rail<br />

35 mm, length 830 mm<br />

for 900 mm cabinets<br />

<strong>SIMATIC</strong> S5, standard DIN rail<br />

35 mm, length 2 m<br />

6ES5 710-8MA21<br />

6ES5 710-8MA31<br />

6ES5 710-8MA41<br />

1) An MMC is absolutely essential for operating the CPU<br />

Siemens ST 70 · 2005<br />

10/15<br />

10