Trend Micro InterScan <strong>Messaging</strong> <strong>Security</strong> <strong>Virtual</strong> <strong>Appliance</strong> Administrator’s Guide<br />

Troubleshooting<br />

32-2<br />

Table 32-1 shows common issues that you might encounter when configuring or<br />

administering IMSVA. If you have additional problems, check the Trend Micro<br />

Knowledge Base.<br />

For troubleshooting and FAQ information pertaining to the deployment of IMSVA,<br />

refer to the IMSVA Installation Guide.<br />

TABLE 32-1. Troubleshooting issues<br />

General<br />

ISSUE DESCRIPTION AND RESOLUTION<br />

Unable to access<br />

the Web console<br />

or other components.<br />

No access to the<br />

Web management<br />

console<br />

The target port is not in the firewall approved list. Open<br />

the ports as shown inTable 32-2 on page 32-14 in the firewall.<br />

If you are unable to access the Web console, do the following:<br />

1. Start the database process, dbctl.sh, before<br />

starting the Central Controller process, S99ADMINUI.<br />

2. If you are still unable to access the Web console,<br />

restart the Central Controller process, S99ADMINUI.<br />

For more details, refer to Using IMSVA Scripts on page B-2.<br />

The Web management console URL is not a trusted site<br />

in Internet Explorer. Add the URL to the trusted sites.