06.08.2013 Views

Test Plan for Optical Grooming Switches - Light Reading

Test Plan for Optical Grooming Switches - Light Reading

Test Plan for Optical Grooming Switches - Light Reading

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Other comments:<br />

None<br />

Current route and status.<br />

Main route and Status.<br />

Protection Route and Status.<br />

Available resources.<br />

TCA013: Confirm 1+1 MSP does not revert<br />

Purpose:<br />

To confirm 1+1 MSP is not revertive<br />

<strong>Test</strong> method:<br />

1. Following on from successful completion of TCA012<br />

2. Replace card PAR#6<br />

3. Note results on SDH testers and switch management system<br />

<strong>Test</strong> <strong>Plan</strong> <strong>for</strong> <strong>Optical</strong> <strong>Grooming</strong> <strong>Switches</strong><br />

Expected result:<br />

Card out alarm should be cleared<br />

SDH testers should show no further loss of traffic<br />

Switch management system should still show STS-1 circuit routed via PAR#7-<br />

LON#1 trunk<br />

Other comments:<br />

None<br />

TCA014: Confirm manual switch of 1+1 MSP<br />

Purpose:<br />

To confirm 1+1 MSP can be manually switched correctly<br />

<strong>Test</strong> method:<br />

1. Following on from successful completion of TCA013<br />

2. Manually switch STS-1 circuit from PAR#7-LON#1 trunk to PAR#6-LON#2 trunk<br />

Expected result:<br />

STS-1 circuit should see sub-50 ms loss of traffic<br />

Switch management system should show alarm indicating manual switch<br />

Switch management system should show STS-1 circuit now routed PAR#6-<br />

LON#2<br />

Other comments:<br />

None<br />

TCA015: Confirm loss of protection route on 1+1 MSP is handled correctly<br />

Purpose:<br />

To confirm loss of protection route on 1+1 MSP is handled correctly<br />

<strong>Test</strong> method:<br />

1. Following on from successful completion of TCA014<br />

2. Break fibre PAR#7-LON#1<br />

Expected result:<br />

No loss of traffic on SDH testers<br />

Switch management system shows circuit routings unchanged<br />

23

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!