Test Plan for Optical Grooming Switches - Light Reading
Test Plan for Optical Grooming Switches - Light Reading
Test Plan for Optical Grooming Switches - Light Reading
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Test</strong> <strong>Plan</strong> <strong>for</strong> <strong>Optical</strong> <strong>Grooming</strong> <strong>Switches</strong><br />
Expected result:<br />
• Expect to measure AU-AIS at B and to record ODI back at A.<br />
• Management system should indicate AIS occurring outside the TCM section.<br />
TCA049: Link test.<br />
Purpose:<br />
To check TCM source <strong>for</strong> errors<br />
<strong>Test</strong> method:<br />
• Set A and B to terminate the TCM bytes.<br />
• Terminate TCM at A and B<br />
• Insert B3 errors in A, using tester No.1.<br />
Expected result:<br />
• Expect to measure same number at B using tester No. 4.<br />
• The inserted TC-APId, number ofB3 errors and IEC of the TCM source can be<br />
verified with tester No. 2.<br />
• The B3 errors measured at tester No. 4 must agree with B3 errors transmitted by<br />
tester No. 1 and with the B3 and IEC errors measured at tester No. 2.<br />
• The N byte is terminated at B.<br />
• Management system should indicate errors occurring outside the TCM section.<br />
Any other comments:<br />
None<br />
END OF BLOCK 8<br />
BLOCK 9. Transparency of vendors system to SONET / SDH overhead bytes. TCA53 to TCA57<br />
<strong>Test</strong> Block description:<br />
Investigate Transparency of vendors system to SONET / SDH overhead bytes.<br />
Procedure:<br />
Block of test to be proceeded in sequence from TCA50 to TCA54.<br />
<strong>Test</strong> equipment needed:<br />
Four SONET/SDH test sets.<br />
Switch management system.<br />
Computer running Exact <strong>Test</strong> software interfacing to testers.<br />
<strong>Test</strong> equipment placement and set-up:<br />
A SONET/SDH protocol tester to monitor traffic at Port A.<br />
• Clock from received optical<br />
• <strong>Optical</strong> OC-48<br />
A SONET/SDH protocol tester to monitor traffic at Port B.<br />
• Clock from received optical.<br />
• <strong>Optical</strong> OC-48<br />
A SONET/SDH protocol tester to through-mode within main trunk in direction between Port<br />
A and Port B<br />
• Clock from received data.<br />
• Through mode.<br />
• Out of service, transparent.<br />