2. At A insert legal Tandem Connection Access Point Identifier (TC-APId) as expected by<br />
B<br />
Expected result:<br />
• No alarms/errors expected.<br />
TCA045: <strong>Test</strong> unexpected Tandem Connection Access Point Identifier.<br />
Purpose:<br />
Confirm action when unexpected TC-APId path trace is received at B.<br />
<strong>Test</strong> method:<br />
1. Set A to “Transparent” and B to terminate the TCM bytes.<br />
2. At A insert different TC-APId to that expected at B.<br />
3. Check <strong>for</strong> TC-APId between A & B using testers in through mode.<br />
Expected result:<br />
• May raise alarm on management system.<br />
• Should receive path AIS (AIS-P / AU-AIS) downstream on tester at B.<br />
• B should terminate the N1 byte with “00h”and raise a remote defect indicator<br />
upstream (TC-RDI) (observed at A).<br />
TCA046: Errors with TCM section.<br />
Purpose:<br />
Confirm TCM operation – Errors with TCM section.<br />
<strong>Test</strong> method:<br />
1. Set A to “Transparent” and B to terminate the TCM bytes.<br />
2. Insert B3 errors at tester No. 1.<br />
Expected result:<br />
• Measure same number of B3s at B.<br />
• Measure RDI & OEI (outgoing error indication) at A from B.<br />
• Management system should indicate errors occurring within the TCM section.<br />
TCA047: Errors external to TCM section.<br />
Purpose:<br />
Confirm TCM operation – Errors external to TCM section.<br />
<strong>Test</strong> method:<br />
1. Set A to “Transparent” and B to terminate the TCM bytes.<br />
2. Insert IEC at tester No. 1(incoming error count) in A.<br />
Expected result:<br />
• Expect to measure same number of B3 errors at B and to record OEI back at A.<br />
• Management system should indicate errors occurring outside the TCM section.<br />
TCA048: TC-AIS external to TCM section.<br />
Purpose:<br />
Confirm TCM operation – AIS external to TCM section.<br />
<strong>Test</strong> method:<br />
1. Set A to “Transparent” and B to terminate the TCM bytes.<br />
2. Insert incoming AIS in the IEC into A using tester No. 1.<br />
38