Test Plan for Optical Grooming Switches - Light Reading
Test Plan for Optical Grooming Switches - Light Reading
Test Plan for Optical Grooming Switches - Light Reading
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Equipment needed:<br />
4 SONET test sets<br />
<strong>Test</strong> <strong>Plan</strong> <strong>for</strong> <strong>Optical</strong> <strong>Grooming</strong> <strong>Switches</strong><br />
<strong>Test</strong> method:<br />
1. Follows on from successful completion of TCB005<br />
2. Confirm that lockout is still in place and that circuits are correctly routed and all test sets<br />
are error free<br />
3. Break PAR#1-LA#1 fibre<br />
Expected result<br />
• Within 10 seconds alarm should be raised indicating location of fibre break<br />
• Both the OC3 and OC12c circuits will see a brief loss of traffic – the duration of<br />
which will be recorded in each case<br />
• Switch management system should clearly show that neither trail has been<br />
routed/switched onto PAR#5-LON#1 fibre. The actual routing will be recorded <strong>for</strong><br />
each trail.<br />
Other comments:<br />
Depending on supplier implementation either protection switching or mesh restoration may<br />
occur here – and it may be different <strong>for</strong> the OC3 and OC12c circuits. An obvious measure of<br />
success is that the shorter the loss of traffic the better.<br />
TCB007: Confirm that when lockout is removed the management system allows easy<br />
reoptimisation of network.<br />
<strong>Test</strong> purpose:<br />
Following successful completion of TCB006, the network is in a complex, dual-fault situation<br />
with quite tortuous circuit routings. Once all faults are repaired, it is important that the<br />
operator can easily use the management system to reoptimise circuit routings.<br />
Equipment needed:<br />
4 SONET test sets<br />
<strong>Test</strong> method:<br />
1. Follows on from successful completion of TCB006<br />
2. First confirm that the results of TCB006 are fully and accurately documented<br />
3. Repair the PAR#5-LON#1 fibre and record any traffic loss and reports/alarms on<br />
management system<br />
4. Remove the lockout on PAR#5-LON#2 fibre and record any traffic loss and<br />
reports/alarms on management system<br />
5. Use the management system to automatically reoptimise the network configuration and<br />
circuit routing<br />
6. Note durations of any loss of traffic and confirm circuit routings are back to initial state<br />
Expected result:<br />
• There should be as little impact on traffic as possible<br />
• The automatic reoptimisation process should be easy and intuitive – should take<br />
BTexact no more than 10 minutes<br />
• At the completion of the test the network should be in a stable state – error free, alarm<br />
free and with the circuits returned to their original optimal routings<br />