d) Disconnect the 3-pin connector from<br />

the compressor pins.<br />

e) Disconnect the ground wire from the<br />

compressor terminal.<br />

Ground<br />

Wire<br />

3-Pin<br />

Connector<br />

f) Remove the screw from the chassis<br />

ground wire and remove the inverter.<br />

Ground<br />

Wire &<br />

Screw<br />

9. To remove the condenser fan motor:<br />

a) Remove the hex-head screws from the<br />

fan motor bracket (see the top right<br />

photo).<br />

4-15<br />

Condenser Fan Motor<br />

Bracket Screws<br />

b) Press down on the locking tabs and pull<br />

the wire connector off the fan motor.<br />

c) Remove the speed nut from the blade<br />

and remove the blade from the motor<br />

shaft.<br />

Speed Nut<br />

Connector<br />

d) Remove the two hex-head screws<br />

from the fan motor and remove the<br />

motor from the bracket.<br />

Motor Screws<br />