POWER SWITCH<br />
(1) Unused<br />
(2) WH<br />
(3) Line (Ribbed)<br />
WARNING<br />
Electrical Shock Hazard<br />
Disconnect power before servicing.<br />
Replace all parts and panels before operating.<br />
Failure to do so can result in death or electrical shock.<br />
(4) Unused<br />
(5) BK<br />
(6) Line (Smooth)<br />
Refer to page 4-12 for the procedure for accessing<br />
the power switch.<br />
1. Unplug refrigerator or disconnect power.<br />
2. Disconnect the wires from the power<br />
switch terminals.<br />
3. Set the ohmmeter to the R x 1 scale.<br />
4. Touch the ohmmeter test leads to the following<br />
switch pins. The meter should indicate<br />
as shown:<br />
Switch Off: Pins 2 & 3 = open (infinite)<br />
Pins 5 & 6 = open (infinite)<br />
Switch On: Pins 2 & 3 = closed (0 Ω)<br />
Pins 5 & 6 = closed (0 Ω)<br />
5-3<br />
24 V TRANSFORMER<br />
Primary<br />
Secondary<br />
Refer to page 4-12 for the procedure for accessing<br />
the 24 V transformer.<br />
1. Unplug refrigerator or disconnect power.<br />
2. Disconnect the primary and secondary<br />
transformer connectors.<br />
3. Set the ohmmeter to the R x 1 scale.<br />
4. Touch the ohmmeter test leads to the following<br />
connectors. The meter should indicate<br />
as shown:<br />
Primary = Between 11 & 17 Ω<br />
Secondary = Approximately 1 Ω