SERVICE DIAGNOSTICS MODE<br />

As a requirement to run the Service Diagnostics<br />

routine, the appliance must be turned ON.<br />

The Service Diagnostics Mode is entered by<br />

pressing the following 2 key sequence:<br />

Press and hold the RC Temp Increase key,<br />

and then the Power key, and hold both down<br />

for 3 seconds.<br />

Use the Component Evaluation Mode chart<br />

below to diagnose the components. When the<br />

technician is satisfied that the first component<br />

has passed the test, continue with the next<br />

component evaluation by pressing either the RC<br />

6-2<br />

Temp UP key, or the Up arrow key. The routine<br />

will end automatically after all the steps are<br />

completed, or after 20 minutes have elapsed,<br />

whichever occurs first. The control will then<br />

resume the normal cooling mode.<br />

SERVICE TIP: If the control does not respond,<br />

it may be necessary to remove power from the<br />

refrigerator for a few seconds. Reconnect power,<br />

and perform the service diagnostics routine to<br />

verify that the control is working properly.<br />

If the bimetal is by-passed for testing (if applicable),<br />

do not overheat the evaporator area.