SERVICE DIAGNOSTICS MODE<br />
As a requirement to run the Service Diagnostics<br />
routine, the appliance must be turned ON.<br />
The Service Diagnostics Mode is entered by<br />
pressing the following 2 key sequence:<br />
Press and hold the RC Temp Increase key,<br />
and then the Power key, and hold both down<br />
for 3 seconds.<br />
Use the Component Evaluation Mode chart<br />
below to diagnose the components. When the<br />
technician is satisfied that the first component<br />
has passed the test, continue with the next<br />
component evaluation by pressing either the RC<br />
6-2<br />
Temp UP key, or the Up arrow key. The routine<br />
will end automatically after all the steps are<br />
completed, or after 20 minutes have elapsed,<br />
whichever occurs first. The control will then<br />
resume the normal cooling mode.<br />
SERVICE TIP: If the control does not respond,<br />
it may be necessary to remove power from the<br />
refrigerator for a few seconds. Reconnect power,<br />
and perform the service diagnostics routine to<br />
verify that the control is working properly.<br />
If the bimetal is by-passed for testing (if applicable),<br />
do not overheat the evaporator area.