7-118 RIO Block Transfer<br />

Publication <strong>1747</strong>-<strong>6.22</strong><br />

Control Flag<br />

EN<br />

TO<br />

Status Flag<br />

2<br />

EW<br />

2<br />

ST<br />

ER<br />

DN<br />

Block Transfer Failure After Startup of Transmission Across RIO Link<br />

1 M0 Control Information 4<br />

M1 Status Information<br />

Block Transfer Failure after Startup of Transmission Across the RIO<br />

Link<br />

This example illustrates control and status changes when a BT fails<br />

after it starts.<br />

1. The SLC control program fills in the M0 BT output/control<br />

buffer and sets the EN flag.<br />

2. The scanner detects the EN flag, validates the M0 information,<br />

puts the BT request on the RIO link successfully, and sets the<br />

EW and ST flags in the M1 BT input status buffer.<br />

3. The scanner receives a BT reply (with some error) from the RIO<br />

link device, fills in the M1 BT buffer’s error code field, and sets<br />

the ER flag.<br />

4. The SLC control program detects the ER flag, examines the M1<br />

BT buffer error code, and clears the EN flag after processing the<br />

error.<br />

5. The scanner detects that the SLC control program has processed<br />

the reply in the M1 BT buffer and clears the EW, ST and ER<br />

flags.<br />

3<br />

5<br />

5<br />