5-84 <strong>Scanner</strong> Configuration and Programming<br />
Publication <strong>1747</strong>-<strong>6.22</strong><br />
Bit Number (decimal)<br />
Status Word, Word 0<br />
Baud Rate, Word 2<br />
Primary Device Address, Word 3<br />
Primary Device Size, Word 4<br />
Primary Active Device Status, Word 5<br />
Logical Rack 0 Device Fault Status Word 12<br />
Logical Rack 1 Device Fault Status Word 13<br />
Logical Rack 2 Device Fault Status Word 14<br />
Logical Rack 3 Device Fault Status Word 15<br />
Complementary Logical Device Address, Word 3<br />
Complementary Logical Image Size, Word 4<br />
M1 (Status) File Complementary<br />
G File<br />
15<br />
x<br />
14<br />
x<br />
13<br />
x<br />
x x x<br />
RIO Logical<br />
Rack 11<br />
0 0 1<br />
1<br />
0<br />
x<br />
x<br />
x<br />
x<br />
1<br />
0<br />
x<br />
x<br />
x<br />
x<br />
1<br />
0<br />
x<br />
x<br />
x<br />
x<br />
12<br />
x<br />
x<br />
0<br />
0<br />
0<br />
x<br />
x<br />
x<br />
x<br />
11<br />
x<br />
RIO Communication Retry Counter (M1:e.16 - 47)<br />
10<br />
x<br />
9<br />
x<br />
x x x<br />
RIO Logical<br />
Rack 10<br />
0<br />
0<br />
0<br />
x<br />
x<br />
x<br />
x<br />
0<br />
1<br />
0<br />
x<br />
x<br />
x<br />
x<br />
1<br />
1<br />
1<br />
x<br />
x<br />
x<br />
x<br />
8<br />
x<br />
x<br />
0<br />
0<br />
x<br />
x<br />
x<br />
x<br />
M1 File Status Words 16 through 47 - indicate how many RIO<br />
communication retries the scanner makes to each adapter on the RIO<br />
link if communication problems occur. Each word (16-47) contains a<br />
retry counter for each configured quarter logical rack (words 16-31<br />
are for primary logical racks, 0-3, and 32-47 are for complementary<br />
racks, 8-11). Retry counters are useful for troubleshooting<br />
communication problems (such as electrical noise or poor<br />
communication line connections) between the scanner and any<br />
adapters. The scanner clears the retry counters when going from<br />
Program to Run mode, Test to Run mode, and Program to Test mode.<br />
Note that the display (in words M1:e.16 -31) of retry counters<br />
corresponds to the bits set in the Primary Logical Device Address -<br />
Word 1 of the G file. Likewise, the display (in words M1:e.32-47)<br />
correspond to the bits set in the Complementary Logical Device<br />
Address - Word 3 of the G file.<br />
7<br />
x<br />
6<br />
x<br />
5<br />
x<br />
x x x<br />
RIO Logical<br />
Rack 9<br />
e = slot number of the SLC rack containing the scanner x = not<br />
used/defined<br />
RIO Logical Rack 11<br />
Starting Group<br />
0<br />
1<br />
0<br />
1<br />
1<br />
1<br />
0<br />
0<br />
0<br />
RIO Logical Rack 10<br />
Starting Group<br />
0<br />
0<br />
0<br />
1<br />
1<br />
1<br />
0<br />
0<br />
0<br />
1<br />
0<br />
0<br />
0<br />
0<br />
1<br />
0<br />
1<br />
0<br />
1<br />
0<br />
0<br />
0<br />
0<br />
1<br />
0<br />
1<br />
0<br />
1<br />
0<br />
0<br />
0<br />
0<br />
1<br />
0<br />
1<br />
4<br />
x<br />
x<br />
1<br />
1<br />
1<br />
0<br />
0<br />
0<br />
0<br />
RIO Logical Rack 9<br />
Starting Group<br />
1<br />
1<br />
3<br />
x<br />
2<br />
x<br />
1<br />
1<br />
x x 0<br />
RIO Logical<br />
Rack 8<br />
0<br />
1<br />
1<br />
1 0 0 1<br />
1<br />
1<br />
0<br />
0<br />
0<br />
0<br />
1<br />
1<br />
x x x x<br />
x x x x<br />
x x x x<br />
x x x x<br />
RIO Logical Rack 8<br />
Starting Group<br />
6 4 2 0 6 4 2 0 6 4 2 0 6 4 2 0<br />
1 0 0 1<br />
1<br />
0<br />
0<br />
1<br />
M1 File<br />
M1:e.0<br />
M1:e.2<br />
M1:e.3<br />
M1:e.4<br />
M1:e.5<br />
M1:e.12<br />
M1:e.13<br />
M1:e.14<br />
M1:e.15<br />
Important: Individual quarter logical racks within a device cannot<br />
be faulted. Therefore, only the starting logical group of<br />
the device needs to be monitored.<br />
Important: Your SLC control program cannot initialize/clear retry<br />
counters.