5-64 <strong>Scanner</strong> Configuration and Programming<br />
Publication <strong>1747</strong>-<strong>6.22</strong><br />
Bit Number<br />
I/O Mix, Word 0<br />
Primary/Normal Logical<br />
Device Address,<br />
Word 1<br />
Primary/Normal Logical<br />
Image Size<br />
Word 2<br />
Complementary Logical<br />
Device Address<br />
Word 3<br />
Complementary Logical<br />
Image Size,<br />
Word 4<br />
Example G File Showing Primary and Complementary Device Configurations<br />
In the example that follows, the scanner is configured to<br />
communicate with primary and complementary devices. Below are<br />
the device addresses and image sizes:<br />
• Logical Racks 0/8, Logical Group 2 contain a primary 3/4<br />
logical rack device and a complementary 3/4 logical rack device.<br />
• Logical Racks 1/9, Logical Group 0 contain no primary device<br />
and a complementary 1/2 logical rack device.<br />
• Logical Racks 1/9, Logical Group 6 contain a primary 1/4<br />
logical rack device and a complementary 1/4 logical rack device.<br />
• Logical Racks 2/10, Logical Group 0 contain a primary 3/4<br />
logical rack device and a complementary 1/4 logical rack device.<br />
• Logical Racks 3/11, Logical Group 2 contain a primary 1/4<br />
logical rack device and a complementary 1/2 logical rack device.<br />
• Logical Racks 3/11, Logical Group 6 contain a primary 1/4<br />
logical rack device and no complementary device.<br />
15<br />
0<br />
1<br />
14<br />
0<br />
0<br />
13<br />
12<br />
11<br />
10<br />
Illegal Configuration Examples<br />
1<br />
1<br />
0<br />
RIO Logical Rack 3 Starting RIO Logical Rack 2<br />
Logical Group<br />
Starting Logical Group<br />
6<br />
6<br />
1<br />
0<br />
0<br />
4<br />
RIO Rack 3<br />
Image Size<br />
4<br />
0<br />
2<br />
2<br />
1<br />
0<br />
0<br />
0<br />
0<br />
0<br />
6<br />
0<br />
6<br />
0<br />
0<br />
4<br />
0<br />
4<br />
1<br />
9<br />
0<br />
2<br />
0<br />
2<br />
1<br />
8<br />
0<br />
0<br />
1<br />
0<br />
1<br />
RIO Logical Rack 11<br />
Starting Logical Group<br />
RIO Logical Rack 10<br />
Starting Logical Group<br />
RIO Logical Rack 9 Starting RIO Logical Rack 8 Starting<br />
Logical Group<br />
Logical Group<br />
6 4 2 0 6 4 2 0 6 4 2 0 6 4 2 0<br />
0<br />
1<br />
RIO Rack 11<br />
Image Size<br />
6 4 2<br />
1<br />
1<br />
0<br />
0<br />
0<br />
0<br />
6<br />
0<br />
RIO Rack 2<br />
Image Size<br />
0<br />
RIO Rack 10<br />
Image Size<br />
4<br />
0<br />
0<br />
2<br />
0<br />
1<br />
0<br />
1<br />
Having a primary device configured at Logical Rack 1, Logical<br />
Group 2 (bit 5) would be illegal since this image space is already<br />
being used by a complementary device. Having a complementary<br />
device configured at Logical Rack 10, Logical Group 2 (bit 9) would<br />
also be illegal since this image space is already being used by a<br />
primary device.<br />
7<br />
0<br />
6<br />
1<br />
6<br />
1<br />
1<br />
1<br />
6<br />
0<br />
4<br />
0<br />
4<br />
0<br />
0<br />
0<br />
5<br />
1<br />
2<br />
0<br />
2<br />
0<br />
0<br />
1<br />
4<br />
RIO Logical Rack 1 Starting<br />
Logical Group<br />
6<br />
RiO Rack 1<br />
Image Size<br />
RIO Rack 9<br />
Image Size<br />
4<br />
2<br />
0<br />
0<br />
0<br />
0<br />
0<br />
1<br />
0<br />
1<br />
3<br />
0<br />
6<br />
1<br />
2<br />
0<br />
4<br />
1<br />
1<br />
0<br />
2<br />
1<br />
0<br />
RIO Logical Rack 0 Starting<br />
Logical Group<br />
6 4 2 0<br />
0 0 1 0<br />
0<br />
0<br />
0<br />
0 0 1 0<br />
6<br />
1<br />
RIO Rack 0<br />
Image Size<br />
RIO Rack 8<br />
Image Size<br />
4<br />
1<br />
2<br />
1<br />
0<br />
0