00455GB-2007/R01<br />

Availability, design and specifi cations are subject to change without notice. All rights reserved.<br />

■ Electrical components<br />

1<br />

<strong>Generation</strong> C<br />

E Electrical components<br />

ME MULTIPOL WITH INPUTS*<br />

BA BUSLINK DEVICE NET<br />

BP BUSLINK/PROFIBUS-DP<br />

BS BUSLINK/INTERBUS-S<br />

BF BUSLINK/FIPIO<br />

BM BUSLINK/MODBUS<br />

OPTIONS<br />

00 Without option<br />

EX For use in explosive atmospheres<br />

Inactivation of diagnosis<br />

13** Power 24V DC OFF<br />

(Interbus-S/BS version)<br />

13 + M23 connector<br />

25** For supply<br />

(Interbus-S version)<br />

- - Other options<br />

99<br />

■ 2 Pneumatic components<br />

Multipol WITHOUT inputs/outputs<br />

<strong>Generation</strong> C<br />

Island WITH inputs/outputs<br />

<strong>Generation</strong> C<br />

P Pneumatic components<br />

GR<br />

Spool valve<br />

series and size<br />

2 569 (ØM5 or Ø4mm O.D.instant fi ttings)<br />

3 570 (G1/8 or Ø6mm O.D. instant fi ttings)<br />

4 571 (G1/4)<br />

OPTIONS<br />

00 Without option<br />

36 2 separate pressure supplies<br />

with common exhaust<br />

37 2 separate pressure supplies<br />

with separate exhausts<br />

- -<br />

Other options<br />

99 }<br />

PORTS:<br />

2 - 4<br />

PORTS:<br />

1 - 3 - 5<br />

04<br />

:<br />

16<br />

Connection<br />

G Gaz thread<br />

N NPT thread<br />

Q Instant fi ttings (metric)<br />

Position<br />

0 Top side<br />

Connection<br />

G Gaz thread<br />

N NPT thread<br />

Position<br />

1 Lateral<br />

Number of spool valve<br />

places on the island<br />

▲<br />

▲<br />

C E<br />

GR OPTION<br />

TYPE<br />

OPTION<br />

ORDERING EXAMPLE:<br />

- Reference : CEBP00-E2E2<br />

CP400G0G108-MMGMBJMM<br />

BUSLINK - <strong>Generation</strong> C valve island, PROFIBUS-DP protocol, with 2<br />

PNP input modules and female M12 connectors; island for series 571<br />

spool valves with threaded G1/4 connections including 8 valve places<br />

equipped as follows:<br />

5 5/2 spool valves, type M in positions 1, 2, 4, 7 and 8<br />

1 5/3 spool valve (W1), type G, in position 3<br />

1 5/3 spool valve (W2), type B ,in position 5<br />

1 5/2 spool valve, type J, in position 6<br />

**<br />

▲<br />

C M U<br />

C P<br />

For availability of these<br />

options in ATEX version,<br />

consult us.<br />

▲<br />

-<br />

VALVE ISLANDS - GENERATION C<br />

ORDERING INFORMATION FOR A GENERATION C VALVE ISLAND<br />

When ordering, please specify the electrical compontents 1 the pneumatic components 2 and the optional accessories<br />

* Standard version only<br />

▼ ▼▲<br />

No. of<br />

places<br />

-<br />

Please indicate the type of module<br />

required<br />

Valve position<br />

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16<br />

▲ 4 6 8 10 12<br />

SAME ORDERING EXAMPLE FOR AN ATEX ISLAND<br />

- Reference : CEBPEX-E2E2<br />

CP400G0G110-MMGMBJMMPA<br />

For 8 spool valves, reserve 10 places:<br />

- positions 1 to 8 : spool valves<br />

- position 9 : ATEX protection module type P<br />

- position 10 : blanking plate type A<br />

(In the ATEX version, the position after the last valve is reserved<br />

for the protection module.)<br />

ACCESSORIES (see pages 15 and 16)<br />

▲ ▲ ▲ ▲ ▲ ▲<br />

Electrical modules (max. 4)<br />

1 2 3 4<br />

Type Function of input modules<br />

E1 8 PNP inputs, screw terminals (max. 4 modules)<br />

(standard version only)<br />

E2 8 PNP inputs, M12 connector (max. 4 modules)<br />

E5 16 PNP inputs, M12 connector (max. 2 modules)<br />

Positions for 4 to 16 spool valves (1) in standard version<br />

or 15 spool valves in ATEX version<br />

type Spool valve function<br />

A Blanking plates for electr./pneum. mounting surface<br />

P (2) Protection module (BUSLINK ATEX version)<br />

Z<br />

2<br />

1<br />

3<br />

3/2 NC Solenoid air operated pilot<br />

Spring/Differential returnl<br />

K (3) 2 x Solenoid air operated pilot<br />

3/2 NC Differential return<br />

M<br />

J<br />

G<br />

B<br />

E<br />

4 2<br />

14<br />

12<br />

5 3<br />

14<br />

4<br />

1<br />

2<br />

12<br />

5 3<br />

1<br />

4 2<br />

14 12<br />

5 3<br />

1<br />

4 2<br />

14 12<br />

5 3<br />

1<br />

4 2<br />

14 12<br />

5 3<br />

1<br />

5/2 Solenoid air operated pilot<br />

Differential return<br />

5/2 Solenoid air operated<br />

pilot and return<br />

5/3 Pressure held (W1)<br />

Solenoid air operated pilot<br />

5/3 Pressure applied (W2)<br />

Solenoid air operated pilot<br />

5/3 Exhaust released (W3)<br />

Solenoid air operated pilot<br />

(1) To be defi ned in accordance with the valves and inputs.<br />

(2) In the ATEX version, the position after the last valve is reserved<br />

for the protection module.<br />

For an even number of spool valves n, reserve n+2 positions<br />

(position n+1 for the protection module P, position n+2 for the<br />

blanking plate).<br />

(3) The 2x3/2 NC version exists in GR3 (570) only and is not<br />

available in the ATEX version.<br />

All leafl ets are available on: www.asconumatics.eu<br />

14<br />

16<br />

9