27.09.2013 Views

Identification of the major drivers of 'phenolic' taste in ... - GWRDC

Identification of the major drivers of 'phenolic' taste in ... - GWRDC

Identification of the major drivers of 'phenolic' taste in ... - GWRDC

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

AWRI: <strong>Identification</strong> Of The Major Drivers Of ‘Phenolic’ Taste In White W<strong>in</strong>es<br />

Formal Assessment<br />

Samples were presented to <strong>taste</strong>rs <strong>in</strong> 30 mL aliquots <strong>in</strong> 3-digit-coded, covered, ISO standard w<strong>in</strong>e glasses<br />

at 22–24°C, <strong>in</strong> isolated booths under amber light<strong>in</strong>g. The entire set <strong>of</strong> w<strong>in</strong>es was presented <strong>in</strong> a<br />

randomised order. The assessors were presented with four trays <strong>of</strong> four w<strong>in</strong>es per tray. They were forced<br />

to rest for 90 second between samples, and ten m<strong>in</strong>utes between trays. Dur<strong>in</strong>g <strong>the</strong> ten m<strong>in</strong>ute break<br />

assessors were requested to leave <strong>the</strong> booths. Samples were assessed over four days <strong>of</strong> formal sessions.<br />

Forty-eight w<strong>in</strong>es were assessed <strong>in</strong> triplicate, <strong>the</strong>refore 144 samples were presented <strong>in</strong> total.<br />

The <strong>in</strong>tensity <strong>of</strong> each attribute was rated us<strong>in</strong>g an unstructured 15 cm l<strong>in</strong>e scale from 0 to 10, with<br />

<strong>in</strong>dented anchor po<strong>in</strong>ts <strong>of</strong> “low” and “high” placed at 10% and 90% respectively. Data was acquired us<strong>in</strong>g<br />

FIZZ v 2.46 sensory data acquisition s<strong>of</strong>tware (Biosystèmes, Couternon).<br />

Panel performance was assessed us<strong>in</strong>g Fizz, Senstools (OP&P, The Ne<strong>the</strong>rlands) and PanelCheck<br />

(Matforsk) s<strong>of</strong>tware, and <strong>in</strong>cluded analysis <strong>of</strong> variance for <strong>the</strong> effect <strong>of</strong> sample, judge and presentation<br />

replicate and <strong>the</strong>ir <strong>in</strong>teractions, degree <strong>of</strong> agreement with <strong>the</strong> panel mean and degree <strong>of</strong> discrim<strong>in</strong>ation<br />

across samples (data not shown). All judges were found to be perform<strong>in</strong>g to an acceptable standard.<br />

8.5 Results and Discussion<br />

8.5.1 Standard Chemical Analyses<br />

The experimental w<strong>in</strong>emak<strong>in</strong>g protocol used <strong>in</strong> both years produced uniform w<strong>in</strong>es with<strong>in</strong> fermentation<br />

replicates and with analytical parameters that were with<strong>in</strong> <strong>the</strong> ranges generally expected <strong>of</strong> commercial<br />

white w<strong>in</strong>es (Table 8-2). The w<strong>in</strong>es were also technically sound, with less than 1.7 g/L residual sugar,<br />

medium alcohol levels and low volatile acidity. In 2010 <strong>the</strong> w<strong>in</strong>es made from different varieties were also<br />

uniform with <strong>the</strong> exception <strong>of</strong> pH. Consequently, <strong>in</strong> 2011 <strong>the</strong> w<strong>in</strong>es were carefully managed dur<strong>in</strong>g<br />

v<strong>in</strong>ification and adjusted prior to bottl<strong>in</strong>g to achieve a pH value <strong>of</strong> 3.2 for all w<strong>in</strong>es. Data for <strong>in</strong>dividual<br />

w<strong>in</strong>es are <strong>in</strong> Appendix B, Table B-5 and Table B-9.<br />

71

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!