2) SHUTTER : Electronic shutter mode<br />
Shutter adjusts the light receiving time of CCD. It is used to adjust too bright subject and to reduce<br />
the after-image of the moving object. Using SHUTTER makes the image darker.<br />
Note: If a blinking light source such as a fluorescent lamp is used, flicker occurs. The inverter<br />
fluorescent lamps of high blinking frequency are not like to give influence although the flicker<br />
occurs in case of inverter fluorescent lamps which include low blinking frequency<br />
components.<br />
• OFF : Electronic shutter does not operate.<br />
• PRESET : Shutter operates at the shutter speed set from the following shutter preset speed. It is<br />
selected from 1/100 (59.94Hz mode), 1/60 (50Hz mode), 1/250, 1/500, 1/1000, 1/2000,<br />
1/4000 and 1/10000 second.<br />
• VARIABLE : Shutter operates at the shutter speed set from the following shutter variable speed.<br />
1/59.94 to 1/10087s : (59.94Hz mode)<br />
1/50 to 1/8414s : (50Hz mode)<br />
• AES<br />
: Auto Electronic Shutter<br />
Electronic shutter is automatically controlled according to the brightness of the subject.<br />
Appropriate image level is output even when the amount of light is excessively high.<br />
This function can be used effectively with a microscope having no automatic light<br />
adjustment or a system with a fixed lens iris.<br />
Its shutter speed is limited by the following AES LIMIT setting.<br />
LIMIT can be set in the range below. (AES OFFSET : OFF)<br />
[59.94Hz mode] 1/59.94 to 1/10087s<br />
[50Hz mode] 1/50 to 1/8414s<br />
AES OFFSET<br />
Where fluorescent lamps are driven at 50 Hz, it is sometimes possible to improve<br />
17