19.01.2014 Views

MA-500TR Instruction Manual - ICOM Canada

MA-500TR Instruction Manual - ICOM Canada

MA-500TR Instruction Manual - ICOM Canada

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

MENU MODE OPERATION<br />

6<br />

• Internal GPS<br />

The Internal GPS setting mode allows you to set the internal<br />

GPS settings.<br />

q Push [MENU] to enter the Menu mode.<br />

w Push [∫] or [√] to select “User Setting,” then push [ENT].<br />

e Push [∫] or [√] to select “Internal GPS,” then push [ENT].<br />

r Push [∫] or [√] to select the desired item, then push [ENT].<br />

t Select the desired option, shown in the Menu below.<br />

The procedures are described to the right and continued<br />

on the next page.<br />

y Repeat steps r and t to select other items.<br />

u Push [CLEAR] to save and return to the User Setting<br />

mode.<br />

i Push [CLEAR] twice to exit the Menu mode.<br />

[∫]<br />

[ENT]<br />

[√]<br />

[CLEAR]<br />

[MENU]<br />

<br />

- POS (Position) Smoothing<br />

The GPS data sometimes has a margin of error.<br />

This function smooths your vessel’s position data by averaging<br />

the previous position data to make the data stable.<br />

When your vessel is at anchor, this function is effective.<br />

We recommend you set this to a shorter period if your vessel<br />

is underway, because a longer period setting may take time<br />

to approach your actual position data.<br />

The previous 1 to 10 second position data is averaged, depending<br />

on this setting.<br />

➥ Push [Ω] or [≈] to set the POS Smoothing period between<br />

0 (OFF) and 10 seconds. (default: 0 sec)<br />

- SOG (Speed Over Ground) Smoothing<br />

The GPS data sometimes has a margin of error.<br />

This function smooths your vessel’s SOG data by averaging<br />

the previous SOG data to make the data stable.<br />

When your vessel is at anchor, this function is effective.<br />

We recommend you set this to a shorter period if your vessel<br />

is underway, because a longer period setting may take time<br />

to approach your actual speed data.<br />

The previous 1 to 10 second SOG data is averaged, depending<br />

on this setting.<br />

➥ Push [Ω] or [≈] to set the SOG Smoothing period between<br />

0 (OFF) and 10 seconds. (default: 0 sec)<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

12<br />

13<br />

14<br />

15<br />

16<br />

33

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!