90 CHAPTER 6. EXPERIMENTAL STUDY<br />
(a) ST-DPC (b)<br />
u La<br />
i La<br />
u P a<br />
P<br />
Q<br />
VSF-P-DPC<br />
HC-VSF-P-DPC<br />
FL-VSF-P-DPC<br />
Figure 6.1: Experimental steady state operation <strong>of</strong>: ST-DPC, VSF-P-DPC, HC-<br />
VSF-P-DPC and FL-VSF-P-DPC under 2 kW <strong>of</strong> load.<br />
From the top: (a) line voltage u La (200 V/div), line current i La (10 A/div), VSC<br />
input voltage u P a (200 V/div), (b) referenced P ref and measured P active powers<br />
(500 W/div), and referenced Q ref and measured Q reactive powers (500 var/div)