Predictive Control of Three Phase AC/DC Converters
Predictive Control of Three Phase AC/DC Converters
Predictive Control of Three Phase AC/DC Converters
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
84 CHAPTER 5. INVESTIGATIONS OF CONTROL METHODS PERFORMANCE<br />
(a) (b) CSF-P-DPC<br />
(c)<br />
VF-CSF-P-DPC<br />
Figure 5.11: Experimental steady state system operation under 5% <strong>of</strong> fifth harmonic<br />
distorted line voltage: (a) line voltage u La , line current i La , (b) line voltage<br />
u Lph−ph T HD u factor, (c) line current T HD i factor<br />
(a) (b) CSF-P-DPC<br />
(c)<br />
VF-CSF-P-DPC<br />
Figure 5.12: Experimental steady state system operation under 3% <strong>of</strong> fifth, 3% <strong>of</strong><br />
seventh and 1% <strong>of</strong> eleventh harmonics distorted line voltage: (a) line voltage u La ,<br />
line current i La , (b) line voltage u Lph−ph T HD u factor, (c) line current T HD i<br />
factor