3. Diving with <strong>Galileo</strong><br />
WARNING<br />
If the RBT drops to 0 minutes, your gas supply<br />
is dangerously low and you may not be able<br />
to complete a safe ascent. This may result in<br />
serious injury or death. Do not let the RBT drop<br />
to 0 minutes!<br />
for 12 seconds and during this time the<br />
audible signal goes off. In addition, the RBT<br />
information is displayed in inverted colors<br />
(white on a black background). The audible<br />
signal does not stop unless the RBT grows to<br />
1 minute or more, or if the depth is 6.5m/20ft<br />
or shallower.<br />
English<br />
In CLASSIC confi guration, the alarm<br />
message RBT = 0 MIN is displayed in place<br />
of the no-stop or decompression information<br />
for 12 seconds and during this time the<br />
audible signal goes off. In addition, in the<br />
lower right corner, the RBT information is<br />
displayed in inverted colors (white on a black<br />
background). The audible signal does not stop<br />
unless the RBT grows to 1 minute or more, or<br />
if the depth is 6.5m/20ft or shallower.<br />
In LIGHT confi guration, the alarm message<br />
RBT = 0 MIN is displayed in place of the<br />
no-stop information for 12 seconds and<br />
during this time the audible signal goes<br />
off. In addition, after the text message<br />
extinguishes, the RBT is displayed in inverted<br />
colors (white on a black background) in the<br />
lower right corner. The audible signal does<br />
not stop unless the RBT grows to 1 minute<br />
or more, or if the depth is 6.5m/20ft or<br />
shallower.<br />
In FULL confi guration, the alarm message<br />
RBT = 0 MIN is displayed in place of the<br />
no-stop or decompression information<br />
Additionally, for all confi gurations, if the<br />
tank pressure reaches the specifi ed tank<br />
reserve, the message TANK RESERVE<br />
REACHED is displayed on the screen<br />
for 12 seconds and the tank pressure<br />
information is displayed in inverted colors<br />
(white on a black background).<br />
3.2.6 Low battery<br />
WARNING<br />
Do not start a dive if the REPLACE<br />
BATTERY message is displayed on the<br />
screen on the surface. The computer may fail<br />
to function during the dive and this could lead<br />
to serious injury or death.<br />
During the dive, <strong>Galileo</strong> alerts you of<br />
precarious battery situations in two ways:<br />
- By displaying LOW BATTERY on the<br />
screen. This means you can fi nish the<br />
dive but you should replace the battery<br />
once you return to the surface;<br />
- By displaying REPLACE BATTERY<br />
on the screen. This means you need<br />
to start the procedure to terminate the<br />
dive, as there is not enough energy in<br />
the battery to ensure proper continued<br />
functioning and the computer may fail.<br />
During a REPLACE BATTERY alarm,<br />
the backlight cannot be activated, the<br />
audible warnings and alarms are not<br />
available anymore and the compass<br />
cannot be activated.<br />
47