5. Taking care of <strong>Galileo</strong><br />
- Store it in a cool and dry place. Do not<br />
store it in a damp environment, in nonbreathable<br />
material (such as a plastic<br />
bag) or with conductive material such as<br />
a wet towel.<br />
- Keep it clean: use a mild soap and<br />
water solution, and dry it with a soft<br />
towel. Never use alcohol or any abrasive<br />
material such as steel wool or cleaning<br />
chemicals.<br />
- Keep it out of extreme heat and extreme<br />
cold. Operating temperatures are -10°C<br />
to 50°C/14°F to 122°F.<br />
- Do not expose it to direct sunlight for<br />
extended periods, such as by leaving it<br />
in a car.<br />
- Do not bend or stretch the transmitter,<br />
as this may damage the electrodes.<br />
- Do not dry it with anything other than a<br />
soft towel. Mishandling may damage the<br />
electrodes<br />
5.2.1 Replacing the battery in <strong>Galileo</strong><br />
WARNING<br />
We recommend having the battery of <strong>Galileo</strong><br />
replaced by an authorized SCUBAPRO UWATEC<br />
dealer. The change must be made with particular<br />
care in order to prevent water from seeping in.<br />
The warranty does not cover damages due to<br />
an improper placement of the battery.<br />
<strong>Galileo</strong> stores the tissue saturation information<br />
in non-volatile memory, so the battery can be<br />
replaced at any time between dives without<br />
loss of information.<br />
Procedure:<br />
To replace the battery you need a coin or<br />
the dedicated tool that came with <strong>Galileo</strong><br />
and a clean cloth.<br />
1. Dry <strong>Galileo</strong> with a soft towel.<br />
2. Unscrew the battery cap using a coin<br />
or the dedicated tool.<br />
3. Inspect the o-ring on the battery<br />
cap. If you see traces of seeping<br />
water, damages or defects on the<br />
o-ring, replace the o-ring with an<br />
original UWATEC replacement part<br />
(PN 06.202.693). The o-ring is provided<br />
with the UWATEC battery kit for <strong>Galileo</strong><br />
(PN 06.202.872). When replacing the<br />
o-ring, make sure the new o-ring is in<br />
perfect condition and well lubricated,<br />
and that the o-ring, o-ring groove and<br />
sealing surfaces are free of dust and<br />
dirt.<br />
4. Remove the old battery and dispose of<br />
it in an environmentally friendly way.<br />
5. Check the polarity of the new battery.<br />
<strong>Galileo</strong> can be damaged if you do not<br />
insert the battery correctly. Insert the<br />
battery so that the + side is pointing<br />
out of the battery case.<br />
6. Screw the battery cap back in place.<br />
Turn the cap until it is fl ush with the<br />
surface and the slot on the battery<br />
cap is aligned with the mark on the<br />
housing. Damage to <strong>Galileo</strong> due to<br />
improper placement of the battery cap<br />
is not covered by warranty.<br />
English<br />
WARNING<br />
- A leaking battery cap may lead to the<br />
destruction of <strong>Galileo</strong> by water seeping in<br />
or cause <strong>Galileo</strong> to switch off without prior<br />
notice.<br />
- Always open the battery compartment in a<br />
dry and clean environment.<br />
- Only open the battery compartment to<br />
replace the battery.<br />
7. Check <strong>Galileo</strong> by turning it on.<br />
75