plc advanced functions - 16.38<br />

input ’scanner_value_valid’. The PLC must store this code until the parts pass through the<br />

oven. When the parts leave the oven they are detected by a proximity sensor connected to<br />

’part_leaving’. The barcode value read before must be output to ’barcode_output’. Write the<br />

ladder logic for the process. There can be up to ten parts inside the oven at any time.<br />

8. Write the ladder logic for the state diagram below using subroutines for the states.<br />

FS<br />

ST1<br />

A<br />

B<br />

ST2<br />

D<br />

ST3<br />

C<br />

9. Convert the following state diagram to ladder logic using subroutines.<br />

C<br />

FS A B<br />

X Y Z<br />

D<br />

E<br />