The solution resistance (R sol ) value was always very small compared to R corr <strong>and</strong> was ignored.<br />

Kramers-Kronig (K-K) transformations were applied to the measured data to assess whether or<br />

not invalid EIS data was collected [25, 26]. Particularly, a frequency range where the EIS data<br />

did not follow the K-K transforms was determined from the K-K analysis. The remaining valid<br />

frequency range was then used to fit the EIS data into the EC showed in Figure 6.1. In this work,<br />

the regression of process models was the chosen method to validate the EIS data collected <strong>and</strong> an<br />

explanation can be found elsewhere [27].<br />

C c<br />

R s<br />

R f<br />

R p<br />

Pore<br />

C dl<br />

Figure 6.1. Equivalent circuit used for modeling of EIS data.<br />

5.6.1.3 Results<br />

Solution<br />

Coating<br />

Substrate<br />

5.6.1.3.1 Exposure testing. Figure 6.2 shows the results of the exposure testing for the 15<br />

coating systems examined. Results are reported as time to failure (TTF) indicating the first<br />

instance of any form of visual degradation in the coating. Three main observations can be made.<br />

First, Metallast <strong>and</strong> PreKote conversion coatings, regardless of the primer used, failed at<br />

exposure times of less than 196 h. Second, combinations of Alodine, Boegel <strong>and</strong> T5900<br />

conversion coatings combined with Deft or Hentzen primers showed good corrosion resistance at<br />

longer exposure times. In fact all of these samples, except the sample with the Alodine<br />

conversion coating <strong>and</strong> the Hentzen primer, showed no indications of corrosion after 1000 hours<br />

of exposure. Third, samples prepared with Sicopoxy primers all failed in 196 hours or less of<br />

exposure irrespective of the type of conversion coating used.<br />