29.08.2014 Views

2011 Electric Service Requirements Manual, 2nd - Pacific Power

2011 Electric Service Requirements Manual, 2nd - Pacific Power

2011 Electric Service Requirements Manual, 2nd - Pacific Power

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ÉÉÉ<br />

ÉÉÉ<br />

ÉÉÉ<br />

ÉÉÉ<br />

ÉÉÉ<br />

ÉÉÉ<br />

Í<br />

Í<br />

Í<br />

Í<br />

Í<br />

Í<br />

Í<br />

Í<br />

Í<br />

Í<br />

Í<br />

Í<br />

ÉÉÉ<br />

ÉÉÉ<br />

ÉÉÉ<br />

ÉÉÉ<br />

ÉÉÉ<br />

ÉÉÉ<br />

Í<br />

Í<br />

Í<br />

Í<br />

Í<br />

Í<br />

Í<br />

Í<br />

Í<br />

Í<br />

Í<br />

Í<br />

<strong>2011</strong> <strong>Electric</strong> <strong>Service</strong> <strong>Requirements</strong>, 2 nd Edition<br />

Section 5<br />

Figure 5.1.1 − Meter Socket Clearance <strong>Requirements</strong><br />

36” min. clear wall space<br />

ceiling or obstruction<br />

10” min.<br />

ÉÉÉÉÉÉÉÉÉÉÉÉÉ<br />

ÉÉÉ<br />

ÉÉÉ<br />

ÉÉÉ<br />

ÉÉÉ<br />

9” min.<br />

78” min.<br />

head room<br />

ÉÉÉ<br />

ÉÉÉ<br />

wall or obstruction<br />

ÉÉÉ<br />

ÉÉÉ<br />

ÉÉÉ<br />

ÉÉÉ<br />

No obstructions are allowed<br />

directly below the meter.<br />

finished grade (established prior to setting the meter)<br />

HORIZONTAL CLEARANCE<br />

Flush or surface mount<br />

VERTICAL CLEARANCE<br />

Flush or surface mount<br />

Building surface shall<br />

not project beyond<br />

face of box.<br />

ÍÉ<br />

ÍÉ<br />

Í<br />

Í<br />

2”x4” block between<br />

studs or 5 / 16 ” molly bolt<br />

Í<br />

Í<br />

Í<br />

Í<br />

36” working space<br />

ÍÉ<br />

ÍÉ<br />

ÉÍ<br />

ÍÉ<br />

Í<br />

Í<br />

36” working space<br />

Í<br />

Í<br />

Í<br />

Í<br />

4’ min.<br />

6’ max.<br />

ÍÉ<br />

ÍÉ<br />

finished grade (established prior to setting the meter)<br />

Í<br />

Í<br />

FLUSH MOUNT METER<br />

SURFACE MOUNT METER<br />

Requirement:<br />

The minimum unobstructed working space required in front of a single meter is 78 inches high,<br />

36 inches wide, and 36 inches deep (NEC 110.26 A). For current transformer (CT) and<br />

switchboard installations, see Section 10.<br />

Note: Dimensions do not refer to meters housed in EUSERC-approved switchboards or<br />

enclosures, such as EUSERC 354.<br />