In vSwitch1, two VMkernel ports have been created (VMkernel 1 <strong>and</strong> VMkernel 2). Each VMkernel port has<br />
been configured with an IP address on a different subnet, <strong>and</strong> the NIC Teaming properties of each VMkernel<br />
port have been configured as follows.<br />
• VMkernel 1: IP address set to 192.168.1.101.<br />
• VMkernel 1 Port Properties:<br />
o<br />
Enable the Override vSwitch Failover Order option.<br />
o<br />
For NFS <strong>and</strong> iSCSI set Active Adapter to vmnic1.<br />
o<br />
For NFS set St<strong>and</strong>by Adapter to vmnic2.<br />
o<br />
For iSCSI set no St<strong>and</strong>by Adapters.<br />
• VMkernel 2: IP address set to 192.168.2.101.<br />
• VMkernel2 Port Properties:<br />
o<br />
Enable the Override vSwitch Failover Order option.<br />
o<br />
For NFS <strong>and</strong> iSCSI set Active Adapter to vmnic2.<br />
o<br />
For NFS set St<strong>and</strong>by Adapter to vmnic1.<br />
o<br />
For iSCSI set no St<strong>and</strong>by Adapters.<br />
Figure 34) ESX Server VMkernel port properties with traditional Ethernet.<br />