PART 3: SECTION 8.2<br />

FLEXIBLE DROPS<br />

Product<br />

Name<br />

Length<br />

(mm)<br />

Nominal Size/Connection<br />

Supply<br />

YN25-3700 3700 R1(1"BSPT) or 1"NPT or<br />

R1.1/4 (1.1/4"BSPT) External<br />

thread<br />

Nominal Size/Connection<br />

Outlet<br />

Rc1/2 or Rc3/4 (½" or ¾" BS PT)<br />

or<br />

NPT) Internal thread<br />

Maximum<br />

Working<br />

Pressure<br />

(bar)<br />

16<br />

LPCB Ref.<br />

No.<br />

These products have been approved as a Type 2 hose of moderate flexibility in accordance with LPS 1261. These may be<br />

used in applications where little or no differential movement between the two ends is expected after installation (e.g. supply<br />

to single <strong>sprinkler</strong>s in suspended ceilings)<br />

1. Tyco Fastflex flexible <strong>sprinkler</strong> connections are approved for use in the following applications:<br />

Pre-calculated<br />

Assembly length (mm) Town’s main Pumped Fully Hydraulically calculated<br />

700 Up to 2 x 90° bends Up to 2 x 90° bends Up to 2 x 90° bends<br />

Up to 1200 No Up to 2 x 90° bends Up to 2 x 90° bends<br />

Up to 1500 No No Up to 2 x 90° bends<br />

Up to 3700 No No Up to 3 x 90° bends<br />

All pipework supplying Fastflex flexible <strong>sprinkler</strong> connection assemblies in pre-calculated <strong>systems</strong> shall be sized as<br />

distribution mains.<br />

The above restrictions apply to Fastflex which includes a <strong>sprinkler</strong> reducer. Straight lengths can be used with a 90° outlet.<br />

2. In suspended ceilings Fastflex flexible <strong>sprinkler</strong> connections must be installed in accordance with Fastflex Installation Guide Rev<br />

1.<br />

3. In suspended ceilings, outlet reducer must be secured to the ceiling support system with brackets supplied. For other<br />

applications the installer must supply brackets to ensure <strong>sprinkler</strong> is secure.<br />

Victaulic Company<br />

4901 Kesslersville Road, Easton, Pennsylvania 18040, USA<br />

Tel: +1 610 559 3300 • Fax: +1 610 250 8817<br />

E-mail: victaulic@victaulic.com • Website: www.victaulic.com<br />

Certificate No: 104l<br />

Victaulic VicFlexTM AH2 braided flexible <strong>sprinkler</strong> drops<br />

Product<br />

Name<br />

Length<br />

(mm)<br />

Nominal<br />

Size/Connection Supply<br />

Nominal Size/Connection<br />

Outlet<br />

AH2-31 790 1"BSPT (or NPT) External<br />

thread<br />

½" or ¾" BSPT (or NPT)<br />

AH2-36 915 1"BSPT (or NPT) External<br />

thread<br />

AH2-48 1220 1"BSPT (or NPT) External<br />

thread<br />

AH2-60 1525 1"BSPT (or NPT) External<br />

thread<br />

AH2-72 1830 1"BSPT (or NPT) External<br />

thread<br />

Internal thread<br />

½" or ¾" BSPT (or NPT)<br />

Internal thread<br />

½" or ¾" BSPT (or NPT)<br />

Internal thread<br />

½" or ¾" BSPT (or NPT)<br />

Internal thread<br />

½" or ¾" BSPT (or NPT)<br />

Internal thread<br />

Maximum Working LPCB Ref.<br />

Pressure (bar) No.<br />

16 104l/01<br />

16<br />

16<br />

16<br />

16<br />

These products have been approved as a Type 2 hose of moderate flexibility in accordance with LPS 1261.<br />

These may be used in applications where little or no differential movement between the two ends is expected<br />

after installation (e.g. supply to single <strong>sprinkler</strong>s in suspended ceilings)<br />

1. Victaulic flexible <strong>sprinkler</strong> connections are approved for use in the following applications:<br />