PART 3: SECTION 1.3<br />

LPS 1148 APPROVED SPRINKLER CONTRACTORS - OVERSEAS<br />

LPS 1148 is a new scheme for installers of automatic fire <strong>sprinkler</strong> <strong>systems</strong> based overseas. This scheme is<br />

open to all Contractors operating anywhere in the World except the UK & Irel<strong>and</strong> <strong>and</strong> The Netherl<strong>and</strong>s where<br />

LPCB operates different schemes for installers of automatic <strong>sprinkler</strong> <strong>systems</strong>.<br />

Scheme Structure<br />

There are 4 approval levels for Sprinkler Contractors in the LPS 1148 scheme. Figure 1 below shows the<br />

Categories of Work that are allowed to be carried out at each approval level in the LPS 1148 scheme.<br />

Figure 1<br />

Category of Work<br />

Approval level<br />

1 2 3 4<br />

A<br />

Pre-calculated ordinary hazard <strong>systems</strong>,<br />

installations, extensions <strong>and</strong> alterations<br />

(excluding <strong>water</strong> supplies) <br />

B<br />

Pre-calculated high hazard <strong>systems</strong>,<br />

installations, extensions <strong>and</strong> alterations<br />

(excluding <strong>water</strong> supplies) <br />

C Town’s main <strong>water</strong> supplies <br />

D Pumped <strong>water</strong> supplies <br />

E<br />

F<br />

Base build contracts (pre-calculated design<br />

principles) <br />

Systems, installations, extension <strong>and</strong><br />

alterations involving FHC design principles <br />

Installation st<strong>and</strong>ard<br />

Sprinkler contractors will be assessed for their capability to design, install, test & commission <strong>and</strong> service<br />

(where undertaken) automatic fire <strong>sprinkler</strong> <strong>systems</strong> using their national <strong>sprinkler</strong> st<strong>and</strong>ard.<br />

Important note to Specifiers<br />

Specifiers should only use Sprinkler Contractors that are LPS 1148 approved to the appropriate level<br />

depending on the type of <strong>sprinkler</strong> work required, refer to the individual company listings for the approval level<br />

of Sprinkler Contractors.<br />

Listing of Sprinkler Contractors<br />

LPS 1148 Approved Sprinkler Contractors are listed alphabetically, regardless of their approval level.<br />

Continual assessment<br />

LPS 1148 approved <strong>sprinkler</strong> contractors are continually assessed for their continued capability to undertake<br />

<strong>sprinkler</strong> contracts <strong>and</strong> for their compliance with the requirements of the LPS 1148 scheme.<br />

Certificates of Conformity<br />

In order to ensure that a <strong>sprinkler</strong> system is effective, specifiers should always request an LPS 1148<br />

Certificate of Conformity. An LPS 1148 Certificate of Conformity may only be issued for a <strong>sprinkler</strong> system,<br />

installation, extension or alteration that is in full compliance with the one of the acceptable installation<br />

st<strong>and</strong>ards.<br />

Any agreed minor deviations to the installation st<strong>and</strong>ard will be recorded on the LPS 1148 Certificate of<br />

Conformity. A certificate of conformity cannot be issued if there is a major deviation to the installation<br />

st<strong>and</strong>ard. It should be noted that a Sprinkler Contractor's Completion Certificate is NOT an LPS 1148<br />

Certificate of Conformity.<br />