PART 3: SECTION 11.1<br />

SPRINKLER HEADS<br />

Product Name<br />

Nominal Type Temperature Rating ( o C) LPCB Ref. No.<br />

Orifice<br />

Size<br />

(mm)<br />

15 SU 57, 68, 79, 93, 141, 182 (5mm bulb)<br />

15 WU/P 57, 68, 79, 93, 141, 182 (5mm bulb)<br />

† GW-S (1),(3) 20 CU/P 57, 68, 79, 93, 141, 182 (5mm bulb)<br />

20 SP 57, 68, 79, 93, 141, 182 (5mm bulb)<br />

20 SU 57, 68, 79, 93, 141, 182 (5mm bulb)<br />

† GW-S (1) 20 SP 57, 68, 79, 93, 141, 182 (5mm bulb)<br />

20 SU 57, 68, 79, 93, 141, 182 (5mm bulb)<br />

20 CU/P 57, 68, 79, 93, 141, 182 (5mm bulb)<br />

† GW-S QR (1),(2) 10 SR 57, 68, 79, 93, 141 084l/02<br />

† GW-S QR (1),(4) 10 SP 57, 68, 79, 93, 141, (quick response)<br />

10 SU 57, 68, 79, 93, 141, (quick response)<br />

† GW-S QR (1),(2),(7) 10 SR 57, 68, 79, 93, 141<br />

† GW-S QR (1),(4),(7) 10 SP 57, 68, 79, 93, 141, (quick response)<br />

10 SU 57, 68, 79, 93, 141, (quick response)<br />

† GW-S QR (1),(2) 15 SR 57, 68, 79, 93, 141<br />

† GW-S QR (1),(4) 15 SP 57, 68, 79, 93, 141, (quick response)<br />

15 SU 57, 68, 79, 93, 141, (quick response)<br />

15 CU/P 57, 68, 79, 93, 141, (quick response)<br />

15 WU/P 57, 68, 79, 93, 141, (quick response)<br />

† GW-S QR (1),(3),(4) 20 SP 57, 68, 79, 93, 141, (quick response)<br />

20 CU/P 57, 68, 79, 93, 141, (quick response)<br />

20 SU 57, 68, 79, 93, 141, (quick response)<br />

† GW-S QR (1),(4) 20 SP 57, 68, 79, 93, 141, (quick response)<br />

20 SU 57, 68, 79, 93, 141, (quick response)<br />

20 CU/P 57, 68, 79, 93, 141, (quick response)<br />

Notes:<br />

1) Also approved with chromium <strong>and</strong> painted finishes.<br />

2) Approved with brass, chrome or coloured recessing cup.<br />

3) This 20mm orifice <strong>sprinkler</strong> is fitted with a pintle to denote that it has a 15mm nominal thread size.<br />

4) The suitability of ‘quick response’ <strong>sprinkler</strong>s for many risks is not yet proven. Use is therefore limited to where the purchaser, authority<br />

having jurisdiction <strong>and</strong>/or insurers consent to its use. Quick response <strong>sprinkler</strong>s must be h<strong>and</strong>led with care due to the fragile nature of<br />

the operating element, with packaging <strong>and</strong> instructions being marked accordingly.<br />

5) This extended coverage horizontal sidewall <strong>sprinkler</strong> should be h<strong>and</strong>led with care to ensure that the deflector is not deformed. After<br />

installation the deflector angle should be checked with the manufacturers gauge to verify its angle of 92.5°.<br />

6) The product manufacturer should be consulted to determine the product fire protection capability <strong>and</strong> installation practice. Available<br />

test evidence <strong>and</strong> the CEA document "Requirements <strong>and</strong> Test Methods for Hotel Room Horizontal Sidewall Sprinklers" should also<br />

be consulted to ensure correct usage in light hazard applications.<br />

7) This <strong>sprinkler</strong> is fitted with a pintle to denote that it has a 15mm nominal thread size.<br />

Minimax GmbH & Co. KG<br />

Industriestrasse 10/12, D-23840 Bad Oldesloe, Germany<br />

Tel: +49 4531 803 8064 • Fax: +49 4531 803 500<br />

Website: www.minimax.de<br />

Certificate No: 1118a to EN12259-1<br />

Sprinkler Heads<br />

Product Name Nominal orifice size (mm) Type Temperature rating (°C) LPCB Ref. No.<br />

† Minimax MX5-SP-24 15 SP 57, 68, 79, 93, 141, (5mm bulb) 1118a/01<br />