STEP 7 - REMOVE LOCKING BRACKETS<br />

1. Push the control switch to RAISE position<br />

to moderately pressurize hydraulic<br />

system. Remove tack weld from installation<br />

bracket (FIG. 25-1B). Next, unbolt<br />

installation bracket (FIG. 25-1B) from<br />

RH side of extension plate (FIG. 25-<br />

1A). Repeat for LH side.<br />

WARNING<br />

!<br />

To prevent possible injury, never work in the area under the platform. Get access<br />

to the locking angle from the back of the Liftgate.<br />

NOTE: To operate Liftgate, locking bracket must be removed.<br />

2. Remove clamps from forklift and<br />

Liftgate. If wood supports were<br />

used between forklift and ICC<br />

bumper, remove the supports.<br />

Back out forklift (FIG. 25-2).<br />

FIG. 25-1A<br />

FLAT<br />

WASHER<br />

INSTALLATION<br />

BRACKET<br />

NUT<br />

FIG. 25-1B<br />

TOP OF<br />

EXTENSION<br />

PLATE<br />

TACK<br />

WELD<br />

11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713<br />

25<br />

FIG. 25-2