To activate manually a push button needs to be hardwired to the (-) activation<br />

input on the remote start unit. When the vehicle is running press the button the<br />

appropriate amount of times to activate the remote start (factory setting is for 1<br />

pulse). The remote emits a confirmation tone. You can then turn off the ignition<br />

<strong>and</strong> the car will stay running for the pre programmed amount of time.<br />

Note: For this feature to work the “turbo timer run time” mode needs to be programmed<br />

ON <strong>and</strong> the tachometer wire on the remote start needs to be connected<br />

<strong>and</strong> programmed.<br />

3-7 TIMER MODE RUN TIME—12min (1), This is the default setting. Selects<br />

the time in minutes that the system will operate the engine until the system<br />

"times out" when the remote start activates in timer mode. Use the two-chirp<br />

setting for 3(2), 6 (3), 9 (4) MINUTES: This is the maximum operation period <strong>and</strong><br />

the system may be shut down using a shutdown at any time. Using the Bitwriter®,<br />

the run time can be programmed for any duration from 1-16 minutes.<br />

Note: The numbers in parentheses indicate the number of times the <strong>LE</strong>D will<br />

flash.<br />

3-8 F<strong>LE</strong>X RELAY FUNCTION: Ignition 2 (1) In the factory setting, the flex relay<br />

will function the same as the pink ignition 1 wire, in accessory setting the flex<br />

relay will function the same as the Orange accessory 1 wire, in starter setting the<br />

flex relay will function the same as the purple starter 1 wire.<br />

3-9 DIESEL TIMER—WAIT-TO-START INPUT - Timed 15, 30, 45 SECONDS:<br />

Default is the “Wait-to-<strong>Start</strong>” input control wire, or programmable to ignore the<br />

input control wire by a delay of 15 (2), 30 (3), or 45(3) seconds. This feature can<br />

also be optionally programmed with the Bitwriter®, with a delay from 1 to 90<br />

seconds.<br />

Note: The numbers in parentheses indicate the number of times the <strong>LE</strong>D will<br />

flash.<br />

3-10 ACCESSORY STATE DURING WAIT-TO-START ON: This feature will allow the<br />

selection of the accessory output to be ON or OFF during wait-to-start. Use the<br />

two-chirp setting for OFF.<br />