PMS 4500 FCB Manual - Ysebaert
PMS 4500 FCB Manual - Ysebaert
PMS 4500 FCB Manual - Ysebaert
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Mode of Operation of the Generator<br />
Thermo-switch exhaust elbow<br />
If the impeller pump should fail, the raw<br />
water stream fed here tears off and the<br />
exhaust elbow heats up immediately<br />
extremely fast, since the cooling water is<br />
missing. The thermo-switch supervises<br />
thus a functioning raw water cycle.<br />
Thermo-switch in the generator coil<br />
1<br />
2<br />
3<br />
1. Generator coil<br />
2. Thermo-switch<br />
3. Housing<br />
For the protection of the generator coil<br />
there are two thermo-switches inside the<br />
coil, which are for inserted parallel and<br />
safety's sake independently from each<br />
other.<br />
Fig. A.1: Thermo-switch coil<br />
Oil pressure switch<br />
The combustion engine possesses an oil<br />
pressure control switch, which switches<br />
the engine off if the oil pressure drops<br />
under a certain value.<br />
Page 6 <strong>PMS</strong>_<strong>4500</strong>_<strong>FCB</strong>_manual.V02 - Chapter A: Mode of Operation of the Generator 15.7.05