Mode of Operation of the Generator<br />

Thermo-switch exhaust elbow<br />

If the impeller pump should fail, the raw<br />

water stream fed here tears off and the<br />

exhaust elbow heats up immediately<br />

extremely fast, since the cooling water is<br />

missing. The thermo-switch supervises<br />

thus a functioning raw water cycle.<br />

Thermo-switch in the generator coil<br />

1<br />

2<br />

3<br />

1. Generator coil<br />

2. Thermo-switch<br />

3. Housing<br />

For the protection of the generator coil<br />

there are two thermo-switches inside the<br />

coil, which are for inserted parallel and<br />

safety's sake independently from each<br />

other.<br />

Fig. A.1: Thermo-switch coil<br />

Oil pressure switch<br />

The combustion engine possesses an oil<br />

pressure control switch, which switches<br />

the engine off if the oil pressure drops<br />

under a certain value.<br />