Installation Instructions<br />
D.7 Generator 12V DC System-Installation<br />
The Panda <strong>4500</strong> needs a battery with a capacity of at least 44Ah for the start. The generator can<br />
be attached to the existing starting battery of the main engine or be supplied with its own battery.<br />
The Panda <strong>4500</strong> is not equipped with its own 12V battery loading installation. Thus that the starting<br />
battery is charged during the generator operation, at the exit of the generator a battery charger<br />
is ensured is normally attached. This battery charger should be selected in such a way that<br />
the rated output approx. 10% of battery capacity correspond. (120Ah starting battery requires a<br />
battery charger with approx. 10 - 12A charging current).<br />
In the Panda accessories program special battery chargers are available, which are designed to<br />
load in connection with the generator particularly effectively. This is however necessary only if the<br />
electrical system is to be loaded hereby. For loading the generator and/or starting battery a simple,<br />
low-priced battery charger is sufficient.<br />
D.7.1<br />
Connection of the 12V starter battery<br />
The positive (+) battery cable is connected<br />
direcly to the solenoid switch of the<br />
starter.<br />
The negative (-) battery cable is connected<br />
to the engine foot.<br />
Note! - the battery negative pole may<br />
not be connected with the boat ground<br />
or with the protective grounding of the<br />
120V - installation!<br />
Otherwise the danger exists with bad<br />
contact at the battery minus the terminal<br />
box burns out.<br />
Page 54 <strong>PMS</strong>_<strong>4500</strong>_<strong>FCB</strong>_manual.V02 - Chapter D: Installation Instructions 15.7.05