4.6 Wall-mounting the boiler<br />
a<br />
Danger!<br />
Risk of death if the load-bearing capacity<br />
of the fixing elements used is insufficient!<br />
If the fixing elements or wall do not have<br />
sufficient load-bearing capacity, the boiler<br />
can come loose and fall down. This may<br />
also cause leaks in the gas line, which is<br />
potentially fatal.<br />
> When fitting the boiler, ensure that the<br />
fixing elements and the wall have a sufficient<br />
load-bearing capacity.<br />
> Check the quality of the wall.<br />
1<br />
2<br />
3<br />
4.4 Wall-mounting the boiler<br />
> Mount the hanging bracket (1) on the wall using the wall<br />
plugs and screws (2) <strong>pro</strong>vided with the unit.<br />
> Hang the boiler (3) on the hanging bracket from above<br />
using the hanging bracket.<br />
Installation<br />
4.7 Removing/fitting the front casing<br />
4.5 Removing the front casing<br />
Removing the front casing<br />
> Loosen the screw (1) on the bottom of the boiler using a<br />
screwdriver or small spanner.<br />
> Push in both retaining clips (2) on the bottom of the<br />
boiler so that the front casing is released.<br />
> Pull the front casing forwards using the bottom edge.<br />
> Lift the front casing upwards from the bracket.<br />
Fitting the front casing<br />
> Place the front casing on the upper brackets.<br />
> Push the front casing onto the boiler so that until both<br />
retaining clips (2) snap into place at the front casing.<br />
> Fasten the front casing by screwing in the bolt (1) on the<br />
underside of the boiler.<br />