Code Parameters Adjustable values<br />

Adapting the boiler to the heating installation<br />

D.000 Heating partial load Adjustable heating partial load in kW<br />

Auto: Boiler automatically adjusts max. partial load to current<br />

system demand<br />

Factory<br />

setting<br />

Auto<br />

Your own<br />

setting<br />

D.001 Overrun time of internal pump for<br />

heating mode<br />

1 - 60 min 5 min<br />

D.002 Max. burner anti-cycling time heating<br />

at 20 °C flow temperature<br />

2 - 60 min 20 min<br />

D.003 Outlet temp. actual value in °C Not adjustable<br />

D.004 Measured value of hot water sensor Not relevant Not adjustable<br />

D.005 Flow temperature target value (or<br />

return target value)<br />

D.006 Hot water temperature target value<br />

(VUW boilers only)<br />

D.007 Warm start temperature target value<br />

(only with VUW boilers)<br />

Cylinder temperature target value<br />

(only with VU boilers)<br />

In °C, max. of the value set in d.71, limited by an eBUS controller<br />

if connected)<br />

Not adjustable<br />

35 to 65 °C Not adjustable<br />

40 to 65 °C<br />

15 °C frost <strong>pro</strong>tection, then 40 to 70 °C;<br />

(max. temperature can be adjusted under D.020)<br />

D.008 Room thermostat at terminal RT Room thermostat open (no heat requirement)<br />

Room thermostat closed (heat requirement)<br />

D.009 Target value from external eBus controller<br />

Not adjustable<br />

Not adjustable<br />

in °C Not adjustable<br />

D.010 Status of internal pump 1 = on, 0 = off Not adjustable<br />

D.011 Status of external heating pump 1 to 100 = on, 0 = off Not adjustable<br />

D.012 Status of cylinder charge pump Not relevant Not adjustable<br />

D.013 Status of hot water circulation pump Not relevant Not adjustable<br />

D.014 Target pump speed (high-efficiency<br />

pump)<br />

D.015 Actual pump speed (high-efficiency<br />

pump)<br />

D.016 Room thermostat 24 V DC open/<br />

closed<br />

D.017 Heating flow/return regulation<br />

changeover<br />

Not relevant Not adjustable<br />

Not relevant Not adjustable<br />

0 = Room thermostat open (no heating mode)<br />

1 = Room thermostat closed (heating mode)<br />

0 = Flow, 1 = Return 0<br />

Not adjustable<br />

D.018 Pump operating mode setting 1 = Comfort (continuously operating pump)<br />

3 = Eco (intermittently operating pump)<br />

3<br />

D.019 Operating mode of 2-stage pump Not relevant Not adjustable<br />

D.020 Max. setting for cylinder target value Not relevant Not adjustable<br />

D.022 Hot water demand via C1/C2, internal<br />

hot water control system<br />

D.023 Summer/winter operating mode (heating<br />

on/off)<br />

D.025 Hot water generation enabled by eBUS<br />

controller<br />

Not relevant Not adjustable<br />

1 = Heating on, 0 = Heating off (summer mode) Not adjustable<br />

1 = Yes, 0 = No Not adjustable<br />

D.026 Auxiliary relay control Not relevant Not adjustable<br />

11.1 Diagnosis codes<br />

Installation and maintenance instructions <strong>ecoTEC</strong> <strong>pro</strong> 0020129672_03 39<br />