Code Parameters Adjustable values<br />
Adapting the boiler to the heating installation<br />
D.000 Heating partial load Adjustable heating partial load in kW<br />
Auto: Boiler automatically adjusts max. partial load to current<br />
system demand<br />
Factory<br />
setting<br />
Auto<br />
Your own<br />
setting<br />
D.001 Overrun time of internal pump for<br />
heating mode<br />
1 - 60 min 5 min<br />
D.002 Max. burner anti-cycling time heating<br />
at 20 °C flow temperature<br />
2 - 60 min 20 min<br />
D.003 Outlet temp. actual value in °C Not adjustable<br />
D.004 Measured value of hot water sensor Not relevant Not adjustable<br />
D.005 Flow temperature target value (or<br />
return target value)<br />
D.006 Hot water temperature target value<br />
(VUW boilers only)<br />
D.007 Warm start temperature target value<br />
(only with VUW boilers)<br />
Cylinder temperature target value<br />
(only with VU boilers)<br />
In °C, max. of the value set in d.71, limited by an eBUS controller<br />
if connected)<br />
Not adjustable<br />
35 to 65 °C Not adjustable<br />
40 to 65 °C<br />
15 °C frost <strong>pro</strong>tection, then 40 to 70 °C;<br />
(max. temperature can be adjusted under D.020)<br />
D.008 Room thermostat at terminal RT Room thermostat open (no heat requirement)<br />
Room thermostat closed (heat requirement)<br />
D.009 Target value from external eBus controller<br />
Not adjustable<br />
Not adjustable<br />
in °C Not adjustable<br />
D.010 Status of internal pump 1 = on, 0 = off Not adjustable<br />
D.011 Status of external heating pump 1 to 100 = on, 0 = off Not adjustable<br />
D.012 Status of cylinder charge pump Not relevant Not adjustable<br />
D.013 Status of hot water circulation pump Not relevant Not adjustable<br />
D.014 Target pump speed (high-efficiency<br />
pump)<br />
D.015 Actual pump speed (high-efficiency<br />
pump)<br />
D.016 Room thermostat 24 V DC open/<br />
closed<br />
D.017 Heating flow/return regulation<br />
changeover<br />
Not relevant Not adjustable<br />
Not relevant Not adjustable<br />
0 = Room thermostat open (no heating mode)<br />
1 = Room thermostat closed (heating mode)<br />
0 = Flow, 1 = Return 0<br />
Not adjustable<br />
D.018 Pump operating mode setting 1 = Comfort (continuously operating pump)<br />
3 = Eco (intermittently operating pump)<br />
3<br />
D.019 Operating mode of 2-stage pump Not relevant Not adjustable<br />
D.020 Max. setting for cylinder target value Not relevant Not adjustable<br />
D.022 Hot water demand via C1/C2, internal<br />
hot water control system<br />
D.023 Summer/winter operating mode (heating<br />
on/off)<br />
D.025 Hot water generation enabled by eBUS<br />
controller<br />
Not relevant Not adjustable<br />
1 = Heating on, 0 = Heating off (summer mode) Not adjustable<br />
1 = Yes, 0 = No Not adjustable<br />
D.026 Auxiliary relay control Not relevant Not adjustable<br />
11.1 Diagnosis codes<br />