17 Technical data<br />

17 Technical data<br />

<strong>ecoTEC</strong> <strong>pro</strong> Unit <strong>pro</strong> 24 (VUW GB 246/5-3) <strong>pro</strong> 28 (VUW GB 286/5-3)<br />

Nominal heat output range P at 50/30 °C kW 5.7 - 19.9 6.9 - 25.7<br />

Nominal heat output range P at 80/60 °C kW 5.2 - 18.9 6.2 - 24.4<br />

Maximum heat output for hot water generation kW 23.4 28.6<br />

Maximum heat input for hot water generation kW 23.7 28.9<br />

Maximum heat input at the heating side kW 19.1 24.7<br />

Minimum heat input G20 kW 5.5 6.6<br />

Minimum heat input G31 kW — 8.7<br />

Minimum heat output G31 kW — 8.2<br />

Heating setting range<br />

Heating<br />

kW 5 - 19 6 - 24<br />

Max. flow temperature °C 85<br />

Max. flow temperature setting range(factory setting: 75 °C) °C 30-80<br />

Min. pressure for full operation MPa/bar 0.08/0.8<br />

Permissible total over-pressure MPa/bar 0.3/3.0<br />

Expansion vessel capacity l 8<br />

Circulation water quantity (with reference to DT = 20 K) l/h 796 1032<br />

Condensate rate ap<strong>pro</strong>x. (pH value 3.5 – 4.0)<br />

in heating mode 50 °C supply/30 °C return<br />

l/h 1.9 2.5<br />

Remaining feed head of pump (at nominal circulation water<br />

volume)<br />

DHW mode<br />

MPa/bar 0.025/0.25<br />

Lowest water volume l/min 1.5<br />

Water volume (at DT = 42 K) l/min 7.8 9.6<br />

Water volume (at DT = 35 K) l/min 9.4 11.5<br />

Water volume (at DT = 30 K) l/min 11.0 13.4<br />

Permitted overpressure MPa/bar 1.0/10.0<br />

Required connection pressure MPa/bar 0.035/0.35<br />

Hot water output temperature range<br />

General<br />

°C 35-65<br />

Boiler-side gas connection mm 15<br />

Flow/return heating connections, boiler side mm 22<br />

Connecting the hot and cold water, boiler side Inches G 3/4<br />

Connector expansion relief valve (minimum) mm 15<br />

Condensate discharge pipework (minimum) mm 19<br />

Flue gas spigot mm 60/100 (concentric), optional 80/125 (concentric)<br />

Gas connection pressure (gas inlet working pressure)<br />

natural gas, G20<br />

kPa/mbar 0.20/20<br />

Gas connection pressure (gas inlet working pressure)<br />

<strong>pro</strong>pane, G31<br />

Gas flow rate at 15 °C and 1013 mbar<br />

kPa/mbar 0.37/37<br />

(based on hot water generation if applicable) G20 m<br />

G31<br />

3 /h<br />

2.5<br />

3.1<br />

kg/h<br />

1.84<br />

2.25<br />

Flue gas mass flow min./max. g/s 2.5/10.6 3.0 (H gas); 3.9 (P gas)/13.0<br />

Flue gas temperature min./max. °C 40/70 40/75<br />

Certificated flue gas connections C13, C33, C43 , C53, C83, C83, B53P<br />

NOx class 5<br />

NOx mg/kWh 27.3 33.4<br />

SEDBUK (2005) A<br />

SEDBUK (2009) (G20/G31) 89.1/- 89.3/90.3<br />

Boiler dimensions (H x W x D) mm 720 x 440 x 335<br />

Mounting weight ap<strong>pro</strong>x. kg 35 36<br />

Electrical connection V/Hz 230/50<br />

Built-in fuse 2 A, slow-blow<br />

Electrical power consumption min./max. W 90/105<br />

Standby electrical consumption W < 2 < 2<br />

Level of <strong>pro</strong>tection IP X4 D<br />

Certification number CE-0085CM0320<br />

17.1 Technical data<br />

64 Installation and maintenance instructions <strong>ecoTEC</strong> <strong>pro</strong> 0020129672_03