6.2 Connecting the hot and cold water<br />

6.1 Fitting the hot and cold water connection<br />

4<br />

5<br />

> Make the domestic hot and cold water connections as<br />

shown.<br />

> Ensure correct water pressure and flow requirements<br />

and that any expansion can be accommodated with the<br />

cold supply pipe work (¬ section 2.5.7).<br />

6.3 Connecting the heating flow and heating<br />

return<br />

6.2 Fitting the heating flow and heating return<br />

> Make the water connections as shown.<br />

6<br />

7<br />

5<br />

4<br />

3<br />

1<br />

3<br />

2<br />

2<br />

1<br />

6.4 Low loss header<br />

Hydraulic installation<br />

A low loss header disconnects the boiler from the heating<br />

system. The system is no longer dependent on the remaining<br />

feed head of the boiler. In conjunction with the heating<br />

pump, the low loss header ensures that a sufficiently high<br />

minimum quantity of water is always circulating through<br />

the boiler. No electrical accessories are required in order to<br />

use a low loss header.<br />

6.5 Connecting the condensate discharge<br />

pipework<br />

a Danger!<br />

Risk of death from flue gases!<br />

An empty or insufficiently filled condensate<br />

trap may allow flue gas to escape into the<br />

room air.<br />

> Make sure that the condensate trap is<br />

filled with water when switching on the<br />

boiler.<br />

a Danger!<br />

Risk of death from flue gases!<br />

If the condensate discharge pipework is<br />

connected tightly to a fixed connection to<br />

the waste water piping, the internal condensate<br />

trap can be drained fully.<br />

> Do not connect the condensate discharge<br />

pipework tightly to the waste water<br />

piping.<br />

<strong>ecoTEC</strong> <strong>pro</strong> boilers are equipped with a condensate trap<br />

that continually deposits the contents to the discharge pipe.<br />

Installation and maintenance instructions <strong>ecoTEC</strong> <strong>pro</strong> 0020129672_03 21<br />

4<br />

a<br />

3<br />

Internal<br />

stackpipe<br />

b<br />

3<br />

Internal<br />

discharge system<br />

6.3 Condensate discharge pipework<br />

5<br />

c<br />

6<br />

Gulley<br />

1<br />

2<br />

3<br />

7<br />

d<br />

Soakaway<br />

6