18 Glossary<br />

Air/flue gas duct<br />

An air/flue gas duct is a line system with two separate flow<br />

channels. The flue gas is routed into separate chambers at<br />

the same time as the required combustion air is pumped to<br />

the boiler. The air/flue gas duct can be designed as a concentric<br />

or adjacent double flue gas pipe (the flue gas channel<br />

is sealed from the air channel). Floor-standing boilers<br />

and gas-fired wall-hung boilers can be operated as roomsealed<br />

through the air/flue gas duct. As a result, boilers can<br />

be installed in new buildings that do not offer sufficient<br />

combustion air for open-flued heaters due to their airtight<br />

construction.<br />

Burner anti-cycling time<br />

The burner is electronically locked for a specific time after<br />

each time it is switched off ("restart interlock") to avoid frequent<br />

switching on and off of the burner (energy losses)<br />

and to extend the working life of the boiler.<br />

The burner anti-cycling time is only activated for the heating<br />

mode.<br />

Hot water handling is not affected if burner anti-cycling<br />

time is running.<br />

Calorific value<br />

Unlike the heating value, the calorific value of a fuel<br />

describes the total useable heat during combustion, based<br />

on the quantity of fuel used, including the condensation<br />

heat in the steam.<br />

The energy contained in steam can also be used if the<br />

steam liquefies on cooling.<br />

Compact thermal module<br />

The compact thermal module is an assembly of <strong>Vaillant</strong><br />

condensing units that consists of the following four main<br />

components in the <strong>ecoTEC</strong> <strong>pro</strong>: speed-regulated fan, gas-air<br />

mixture fitting, gas supply (mixture pipe) for the premix<br />

burner and premix burner<br />

Condensing technology<br />

Technology which maximises the use of the calorific value<br />

of the fuel. The flue gas is cooled until the water vapour<br />

that it contains condenses. The condensation heat that this<br />

releases can also be used.<br />

In particular, the flue gas losses are greatly reduced. The<br />

losses from conduction of heat and radiation are also<br />

reduced by the lower system temperatures. The entire heating<br />

installation should therefore be designed for low system<br />

temperatures (flow/return temperature) for the effective<br />

use of the calorific value. The level of efficiency attainable<br />

for boilers is always given based on the heating value of the<br />

gas. Due to the additional condensation heat used, the calculated<br />

values can exceed 100 %.<br />

Glossary 18<br />

Digital information and Analysis system (DIA)<br />

The <strong>Vaillant</strong> <strong>ecoTEC</strong> <strong>pro</strong> boiler is fitted with a digital information<br />

and analysis system (DIA). If additional settings are<br />

required, which have not been configured using the installation<br />

assistant, you can view and modify further parameters<br />

using the DIA.<br />

eBUS<br />

eBUS is an abbreviation for energyBUS. The eBUS is a special<br />

bus used in heating technology, which assists the communication<br />

between intelligent components in the heating<br />

technology. In a <strong>Vaillant</strong> system, up to eight different heaters<br />

can be connected via the eBUS.<br />

The eBUS communications <strong>pro</strong>tocol simplifies the controlrelated<br />

linking of different system components within a<br />

heating installation. It <strong>pro</strong>vides particular flexibility for retrofitting<br />

and expanding the system. This simplifies the<br />

installation of boiler cascades or the subsequent addition of<br />

components such as solar hot water generation.<br />

The eBUS <strong>pro</strong>vides extended facilities for connecting controllers.<br />

Multi-functional module<br />

The multi-functional module is an accessory that controls<br />

additional functions or components in combination with<br />

<strong>Vaillant</strong> boilers with eBUS electronics. It also allows you to<br />

select and control 2 in 7, e. g. circulation pump, external<br />

heating pump, external solenoid valve or response from the<br />

flue non-return flap.<br />