<strong>GEA</strong> <strong>CAIRfricostar</strong><br />
Dehumidifier with Air Mixing and Heat Pump Function<br />
Type CAM<br />
– Motor coils for reducing speed of voltage rise du/dt (delta voltage/delta time)<br />
– Numerical display for queries and entering of different indicators on operating status:<br />
control setpoint, motor frequency, actual value and setpoint, motor current,<br />
motor torque and capacity, intermediate circuit voltage, thermal motor load, thermal<br />
frequency converter load, control and programmable display with copy function,<br />
production according to ISO 9001, CE Label, net and main shaft protection according<br />
to VDE 0160, radio interference shielding, codes and regulations on electromagnetic<br />
<strong>com</strong>patibility conform with EN 55011 Kl.B-1; EN 50082-2, electric<br />
insulation of control and power <strong>com</strong>ponents according to VDE 0106/0160 (the use<br />
of earth leakage circuit breaker / fuse with frequency converters NOT possible!),<br />
volume flow measuring device via ring measuring line and pressure measuring<br />
point in fan.<br />
Calculation and evaluation of volume flow via the <strong>GEA</strong> DDC. The settings for entire<br />
unit are done at the factory. Continuous safety monitoring via safety chain in the<br />
unit. Display and settings via <strong>GEA</strong> DDC.<br />
Air damper system – Dampers with sealing lips, leakage volume flow 20 m3/h m2 (dp=100 Pa), for circulating<br />
air/bypass, for fresh and exhaust air. Circulating and fresh air rate 0-100%<br />
– Coated Almg3 damper blades with flow efficient profile, operate in opposite directions.<br />
Driven by double sided, anti-static plastic gears PA6 as fiberglass reinforced<br />
model (resistant to chemicals) including special actuator for each damper<br />
– Control of the individual actuators using continuous DDC signals<br />
Filter for fresh and<br />
exhaust air:<br />
– Filter units conform with VDI 6022<br />
– Including bag filter as of DIN/EN 779, synthetic fiber filter medium<br />
– All filters are fitted with a differential pressure switch for filter-monitoring via the<br />
DDC<br />
Air mixing dehumidifier CAM<br />
Heat recovery system: <strong>GEA</strong> „ECOSTAT2 POWER TUBE“:<br />
– Recuperative heat recovery using <strong>GEA</strong> heat pipe technology, heat exchanger<br />
made of Cu/Al. Aluminium fins, frame elements made of AlMg3, tubes made of oxygen-free<br />
copper charged with R134a CFC-free refrigerant for energy transfer.<br />
– Non-<strong>com</strong>bustible according to fire protection regulation<br />
Heating section: – L.P.H.W. air heater, heat exchanger with copper pipes and drawn aluminium fins in<br />
aluminium frame AlMg3 (max. temp. 110°C, Pmax 16 bar) removable in accordance<br />
with VDI6022;<br />
<strong>GEA</strong> motor 3-way mixing<br />
valve:<br />
Control and regulation<br />
system<br />
– For air reheater, supplied loose including actuator 0-10 V with an automatic step<br />
measurement system for fine adjustment of water flow rate<br />
– Supplied loose, installation by others<br />
– Consists of a separate switch cabinet for mounting on units or separate installation<br />
(depending on unit size), with all necessary <strong>com</strong>ponents for control functions, wired<br />
according to VDE specifications. IP55 electrical connection (via plug or screw terminals)<br />
between control cabinet and unit using factory prepared and fully assembled<br />
lines. Electrical installation for voltage supply, valve mixing control, reheater<br />
pump, if necessary external sensor of the pool water pump and possibly other functions<br />
like remote control inputs by others. The cabinet is supplied loose depending<br />
on the unit size as a stand alone cabinet or for mounting on the unit;<br />
PR-2008-0327-GB • Subject to modifications • Status 05/2009 17