<strong>GEA</strong> <strong>CAIRfricostar</strong><br />

Dehumidifier with Air Mixing and Heat Pump Function<br />

Type CAM<br />

– Motor coils for reducing speed of voltage rise du/dt (delta voltage/delta time)<br />

– Numerical display for queries and entering of different indicators on operating status:<br />

control setpoint, motor frequency, actual value and setpoint, motor current,<br />

motor torque and capacity, intermediate circuit voltage, thermal motor load, thermal<br />

frequency converter load, control and programmable display with copy function,<br />

production according to ISO 9001, CE Label, net and main shaft protection according<br />

to VDE 0160, radio interference shielding, codes and regulations on electromagnetic<br />

<strong>com</strong>patibility conform with EN 55011 Kl.B-1; EN 50082-2, electric<br />

insulation of control and power <strong>com</strong>ponents according to VDE 0106/0160 (the use<br />

of earth leakage circuit breaker / fuse with frequency converters NOT possible!),<br />

volume flow measuring device via ring measuring line and pressure measuring<br />

point in fan.<br />

Calculation and evaluation of volume flow via the <strong>GEA</strong> DDC. The settings for entire<br />

unit are done at the factory. Continuous safety monitoring via safety chain in the<br />

unit. Display and settings via <strong>GEA</strong> DDC.<br />

Air damper system – Dampers with sealing lips, leakage volume flow 20 m3/h m2 (dp=100 Pa), for circulating<br />

air/bypass, for fresh and exhaust air. Circulating and fresh air rate 0-100%<br />

– Coated Almg3 damper blades with flow efficient profile, operate in opposite directions.<br />

Driven by double sided, anti-static plastic gears PA6 as fiberglass reinforced<br />

model (resistant to chemicals) including special actuator for each damper<br />

– Control of the individual actuators using continuous DDC signals<br />

Filter for fresh and<br />

exhaust air:<br />

– Filter units conform with VDI 6022<br />

– Including bag filter as of DIN/EN 779, synthetic fiber filter medium<br />

– All filters are fitted with a differential pressure switch for filter-monitoring via the<br />

DDC<br />

Air mixing dehumidifier CAM<br />

Heat recovery system: <strong>GEA</strong> „ECOSTAT2 POWER TUBE“:<br />

– Recuperative heat recovery using <strong>GEA</strong> heat pipe technology, heat exchanger<br />

made of Cu/Al. Aluminium fins, frame elements made of AlMg3, tubes made of oxygen-free<br />

copper charged with R134a CFC-free refrigerant for energy transfer.<br />

– Non-<strong>com</strong>bustible according to fire protection regulation<br />

Heating section: – L.P.H.W. air heater, heat exchanger with copper pipes and drawn aluminium fins in<br />

aluminium frame AlMg3 (max. temp. 110°C, Pmax 16 bar) removable in accordance<br />

with VDI6022;<br />

<strong>GEA</strong> motor 3-way mixing<br />

valve:<br />

Control and regulation<br />

system<br />

– For air reheater, supplied loose including actuator 0-10 V with an automatic step<br />

measurement system for fine adjustment of water flow rate<br />

– Supplied loose, installation by others<br />

– Consists of a separate switch cabinet for mounting on units or separate installation<br />

(depending on unit size), with all necessary <strong>com</strong>ponents for control functions, wired<br />

according to VDE specifications. IP55 electrical connection (via plug or screw terminals)<br />

between control cabinet and unit using factory prepared and fully assembled<br />

lines. Electrical installation for voltage supply, valve mixing control, reheater<br />

pump, if necessary external sensor of the pool water pump and possibly other functions<br />

like remote control inputs by others. The cabinet is supplied loose depending<br />

on the unit size as a stand alone cabinet or for mounting on the unit;<br />