<strong>GEA</strong> <strong>CAIRfricostar</strong><br />

<strong>GEA</strong> motor 3-way mixing<br />

valve:<br />

Control and regulation<br />

system<br />

The switch cabinet is<br />

supplied with the following<br />

main <strong>com</strong>ponents:<br />

Dehumidifier with Air Recirculating and Heat Pump Function<br />

Type CAU<br />

– Supplied loose for air reheating coil including actuator 230 V with an automatic step<br />

measurement system for fine adjustment of water flow rate<br />

– Supplied loose, installation by others<br />

– Consists of a separate switch cabinet for mounting on units with all necessary <strong>com</strong>ponents<br />

for control functions, wired according to VDE specifications.<br />

– Electrical connection (via plug or screw terminals) between control cabinet and unit<br />

using factory prepared and fully assembled lines.<br />

– Mains voltage for control of mixing valve and reheater pump (including controls)<br />

– Possible output for pool water pump<br />

– The switch cabinet is supplied loose, including fixing material for mounting on the<br />

unit<br />

– All electronic control and regulation <strong>com</strong>ponents can be easily replaced<br />

– Main isolating switch for all pole shut-down of the electrical unit<br />

– Group fuses for fan and <strong>com</strong>pressor<br />

Safety fuse for pump reheater circuit 230V<br />

Control fuse and control voltage supply unit 24V (safety extra-low voltage or SELV)<br />

Control of supply air fan using motor full protection device via PTC<br />

temperature sensor and electronic motor tripping device<br />

– Control of <strong>com</strong>pressor motor with thermal motor protection and interlock for safety<br />

chain and control card, control of icing protection, low and high pressure.<br />

– Electronic control card for <strong>com</strong>pressor regulation with minimum run and standstill<br />

time as clock protection, service reset button, status messages for timer control and<br />

light diode for faults of the refrigeration circuit.<br />

– Humidistat with remote control for mounting in the swimming pool, with status and<br />

fault lamp and operation switch.<br />

Operation with safety extra-low voltage.<br />

Setpoint setting 30-90 % r.h.<br />

Colour: white<br />

On-wall mounting<br />

Dimensions: W/H/D 145/80/30 (mm) supplied loose<br />

– Electronic three point PI-controller for exhaust air temperature control with setpoint<br />

setting on the switch cabinet including installed NTC exhaust air temperature sensor.<br />

– Output 230V for modulating 3-way valve motor in reheater circuit<br />

– If necessary <strong>GEA</strong> pool water temperature control for controlling pool water pump<br />

consisting of an integrated immersion thermostat, interlocking with <strong>com</strong>pressor<br />

operation and output for pool water pump 230V (only control output max. 2A) and<br />

time control for registration of actual values (only in <strong>com</strong>bination with pool water<br />

condenser)<br />

– Output for collective error message signal (floating change-over contact)<br />

– Control possibility of an exhaust fan by others, 2-speed, 230 V/max. 150 W<br />

Air recirculating dehumidifier CAU<br />

PR-2008-0327-GB • Subject to modifications • Status 05/2009 5