<strong>GEA</strong> <strong>CAIRfricostar</strong><br />

Control and regulation<br />

functions:<br />

Dehumidification Unit with Air Mixing and Heat Pump Function<br />

Type CWC<br />

– Status and fault signals in clear text<br />

– Indication of all status and control parameters<br />

– Stepwise access authorization using code<br />

– Integrated clock timer<br />

– Automatic summer / winter time switch-over, activation of weekly programmes, holiday<br />

and special day programmes<br />

– Log for registration of faults with date and time<br />

– Operating hours counter, total operation and maintenance intervals<br />

– Data logging function for most important parameters, can be downloaded<br />

– Separate controls for supply and exhaust air fan motors<br />

– Air volume adjustment and display in m³/h, including monitoring for units with frequency<br />

converters<br />

– Fan motor monitoring using PTC resistor and motor protection relay<br />

– Filter monitoring<br />

– Automatic regulation depending on conditions of fresh air and swimming pool air<br />

– Control sequence with energy recovery, heater and bypass damper<br />

– Exhaust air temperature cascade control with min./max. limitation of supply air temperature<br />

– Cooling with outside air (night cooling)<br />

– Reheater-heat pump consumption control with blockage protection functions<br />

– Continuous humidity control<br />

– Automatic switch-over between active/non-active hours operation<br />

– Continuous inactive/idle mode possible<br />

– Different languages can be selected<br />

– Commissioning function for air dampers<br />

– Inputs: external emergency switch off (e.g. fire protection damper or chlorine gas<br />

alarm)<br />

– Motor monitoring for NE pump can be switched, if required motor protection<br />

by others<br />

– The necessary sensors and actuators are built into the unit or, if necessary,<br />

supplied loose with subsequent installation by others<br />

Technical data<br />

Unit series CWC…S..<br />

Dehumidification<br />

capacity drop<br />

Heating capacity Pres-<br />

sure<br />

Type Unit dimensions Air volume flow<br />

Motor rated power/current<br />

Current<br />

consumption<br />

CWC_S<br />

Total width<br />

Total height<br />

Total length<br />

Minimum<br />

Maximum<br />

Rated (with dehumidification)<br />

Rated (with ventilation)<br />

according to VDI 2089,<br />

at nominal air capacity 1)<br />

[mm] [m3/h] [kg/h] [Pa] [kW/A] [A]<br />

015 760 1480 1640 750 2000 1500 1000 9.5 2.8 16.0 300 0.6/1.4 0.6/1.4 1.3/2.5 5.3<br />

037 760 1800 2760 1500 3600 2500 1667 16 4.8 23.0 300 3.0/6.1 2.2/4.6 2.3/4.5 15.2<br />

Tab. 1: Technical data <strong>CAIRfricostar</strong> CWC_S<br />

1) Swimming pool air condition 30 °C/54 %r.h.; Outdoor air condition 5 °C/85 %r.h.<br />

2) Inlet/outlet temperature 70 °C/50 °C; maximum heating capacity; 2 rows<br />

3) plus controls/regulation/pumps etc.<br />

(All data are approximate values and summarize most important features. Subject to modifications. Exact data are available in the current Lplus<br />

design software<br />

PR-2008-0327-GB • Subject to modifications • Status 05/2009 53<br />

Heat recovery system<br />

Reheater 2)<br />

Ext. fresh/supply air;<br />

exhaust/return air; each<br />

Supply air fan, high speed,<br />

at rated volume flow<br />

Exhaust air fan, high speed,<br />

at rated volume flow<br />

Compressor, without<br />

pool water condenser<br />

Unit total 3)<br />

Air mixing dehumidifier CWC