<strong>GEA</strong> <strong>CAIRfricostar</strong><br />
Control and regulation<br />
functions:<br />
Dehumidification Unit with Air Mixing and Heat Pump Function<br />
Type CWC<br />
– Status and fault signals in clear text<br />
– Indication of all status and control parameters<br />
– Stepwise access authorization using code<br />
– Integrated clock timer<br />
– Automatic summer / winter time switch-over, activation of weekly programmes, holiday<br />
and special day programmes<br />
– Log for registration of faults with date and time<br />
– Operating hours counter, total operation and maintenance intervals<br />
– Data logging function for most important parameters, can be downloaded<br />
– Separate controls for supply and exhaust air fan motors<br />
– Air volume adjustment and display in m³/h, including monitoring for units with frequency<br />
converters<br />
– Fan motor monitoring using PTC resistor and motor protection relay<br />
– Filter monitoring<br />
– Automatic regulation depending on conditions of fresh air and swimming pool air<br />
– Control sequence with energy recovery, heater and bypass damper<br />
– Exhaust air temperature cascade control with min./max. limitation of supply air temperature<br />
– Cooling with outside air (night cooling)<br />
– Reheater-heat pump consumption control with blockage protection functions<br />
– Continuous humidity control<br />
– Automatic switch-over between active/non-active hours operation<br />
– Continuous inactive/idle mode possible<br />
– Different languages can be selected<br />
– Commissioning function for air dampers<br />
– Inputs: external emergency switch off (e.g. fire protection damper or chlorine gas<br />
alarm)<br />
– Motor monitoring for NE pump can be switched, if required motor protection<br />
by others<br />
– The necessary sensors and actuators are built into the unit or, if necessary,<br />
supplied loose with subsequent installation by others<br />
Technical data<br />
Unit series CWC…S..<br />
Dehumidification<br />
capacity drop<br />
Heating capacity Pres-<br />
sure<br />
Type Unit dimensions Air volume flow<br />
Motor rated power/current<br />
Current<br />
consumption<br />
CWC_S<br />
Total width<br />
Total height<br />
Total length<br />
Minimum<br />
Maximum<br />
Rated (with dehumidification)<br />
Rated (with ventilation)<br />
according to VDI 2089,<br />
at nominal air capacity 1)<br />
[mm] [m3/h] [kg/h] [Pa] [kW/A] [A]<br />
015 760 1480 1640 750 2000 1500 1000 9.5 2.8 16.0 300 0.6/1.4 0.6/1.4 1.3/2.5 5.3<br />
037 760 1800 2760 1500 3600 2500 1667 16 4.8 23.0 300 3.0/6.1 2.2/4.6 2.3/4.5 15.2<br />
Tab. 1: Technical data <strong>CAIRfricostar</strong> CWC_S<br />
1) Swimming pool air condition 30 °C/54 %r.h.; Outdoor air condition 5 °C/85 %r.h.<br />
2) Inlet/outlet temperature 70 °C/50 °C; maximum heating capacity; 2 rows<br />
3) plus controls/regulation/pumps etc.<br />
(All data are approximate values and summarize most important features. Subject to modifications. Exact data are available in the current Lplus<br />
design software<br />
PR-2008-0327-GB • Subject to modifications • Status 05/2009 53<br />
Heat recovery system<br />
Reheater 2)<br />
Ext. fresh/supply air;<br />
exhaust/return air; each<br />
Supply air fan, high speed,<br />
at rated volume flow<br />
Exhaust air fan, high speed,<br />
at rated volume flow<br />
Compressor, without<br />
pool water condenser<br />
Unit total 3)<br />
Air mixing dehumidifier CWC