Air mixing dehumidifier CWP<br />

<strong>GEA</strong> <strong>CAIRfricostar</strong><br />

Control and regulation<br />

functions:<br />

Dehumidifier with Air Mixing Function<br />

Type CWP<br />

– Status and fault signals in clear text<br />

– Indication of all status and control parameters<br />

– Stepwise access authorization using code<br />

– Integrated clock timer<br />

– Automatic summer / winter time switch-over, activation of weekly programmes,<br />

holiday and special day programmes<br />

– Log for registration of faults with date and time<br />

– Operating hours counter, total operation and maintenance intervals<br />

– Data logging function for most important parameters, can be downloaded<br />

– Separate controls for supply and exhaust air fan motors<br />

– Air volume adjustment and display in m³/h, including monitoring for units with frequency<br />

converters<br />

– Fan motor monitoring using PTC resistor and motor protection relay<br />

– Filter monitoring<br />

– Regulation of air mixing dampers with selectable minimum fresh air rate and maximum<br />

limitation, automatic control depending on conditions of fresh air and swimming<br />

pool air<br />

– Control sequence with energy recovery, heater, bypass damper and air mixing<br />

damper system<br />

– Exhaust air temperature cascade control with min./max. limitation of supply air temperature<br />

– Cooling with outside air (night cooling)<br />

– Reheater-heat pump consumption control with blockage protection functions<br />

– Continuous humidity control<br />

– Automatic switch-over between active/non-active hours operation<br />

– Continuous inactive idle mode possible<br />

– Different languages can be selected<br />

– Commissioning function for air dampers<br />

– Inputs: external emergency switch off (e.g. fire protection damper or chlorine gas<br />

alarm)<br />

– Motor monitoring for reheater pump can be switched, if required motor protection<br />

by others<br />

– The necessary sensors and actuators are built into the unit or, if necessary, supplied<br />

loose with subsequent installation by others<br />

PR-2008-0327-GB • Subject to modifications • Status 05/2009 41