GEA CAIRfricostar - Aspectenvironmental.com
GEA CAIRfricostar - Aspectenvironmental.com
GEA CAIRfricostar - Aspectenvironmental.com
- No tags were found...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>GEA</strong> <strong>CAIRfricostar</strong><br />
Heat recovery system:<br />
Heating section:<br />
<strong>GEA</strong> motor 3-way mixing<br />
valve:<br />
Control and regulation<br />
system<br />
The switch cabinet is<br />
supplied with the following<br />
main <strong>com</strong>ponents:<br />
Dehumidifier with Air Mixing Function<br />
Type CWP<br />
<strong>GEA</strong> „ECOPLAT2 POWER PLATE“<br />
– 2 symmetric high performance plate heat exchangers for recuperative heat<br />
recovery<br />
2 cross flow aluminium plate heat exchangers (corrosion protected Al99 with best<br />
temperature coefficient) in row switch. Surface is additionally coated with thermoplastic<br />
material. Largest possible heat exchange surface using entire unit depth<br />
with minimum pressure losses. Optimal selection with consideration of operation<br />
conditions. Best efficiency rates within entire outdoor temperature range, especially<br />
resistant to corrosion and wear. Swimming pool configuration.<br />
– „Upside Down“ installation for smaller internal pressure drops.<br />
– AlMg3 ventilation tray<br />
– Technical data checked according to EUROVENT<br />
– Conform with VDI 6022<br />
– Non-<strong>com</strong>bustible according to fire protection regulation<br />
L.P.H.W. air heater, heat exchanger with copper pipes and drawn aluminium fins in<br />
aluminium frame AlMg3 (max. temp. 110°C, Pmax 16 bar) removable in accordance<br />
with VDI 6022;<br />
– For air reheater, supplied loose including actuator 0-10 V with an automatic step<br />
measurement system for fine adjustment of water flow rate<br />
– Supplied loose, installation by others<br />
– Consists of a separate switch cabinet for mounting on units or separate installation<br />
(depending in unit size), with all necessary <strong>com</strong>ponents for control functions, wired<br />
according to VDE specifications. IP55 electrical connection (via plug or screw terminals)<br />
between control cabinet and unit using factory prepared and fully assembled<br />
lines. Electrical installation for voltage supply, valve mixing control, reheater<br />
pump, if necessary external sensor and possibly other functions like remote control<br />
inputs by others. The cabinet is supplied loose depending on the unit size as a<br />
stand alone cabinet or for mounting on the unit<br />
– Main isolating switch for all pole shut-down of the electrical unit, lockable<br />
– Group fuses for fan and <strong>com</strong>pressor<br />
– Fuses for reheater 230V/N/PE/50Hz (types 015-083)<br />
3 X 400V/NPE/50Hz (types 100-320)<br />
(if necessary - motor protection by others)<br />
– Control fuses, control transformer 230 V and control voltage supply<br />
unit 24V DC for the digital control<br />
– Control fuse and control voltage supply unit 24V AC for actuators<br />
– Automatic phase controller (option)<br />
– Indoor installation, frost free<br />
Air mixing dehumidifier CWP<br />
PR-2008-0327-GB • Subject to modifications • Status 05/2009 39