DBV-30X Service Manual<br />

CHAPTER<br />

1<br />

1-7-3. When using ID-002 (Pulse) Interface<br />

•DBV-300<br />

Pin No. Signal Name I/O *1 Function Active<br />

1 NC Not Connected<br />

2 NC Not Connected<br />

3 VDD1 DC12V<br />

4 VSS1 DC12V GND<br />

5 NC Not Connected<br />

6 NC Not Connected<br />

7 NC Not Connected<br />

8 NC Not Connected<br />

9 NC Not Connected<br />

10 SG Signal Ground<br />

11 /VEND OUT Accepted denomination Signal Lo<br />

12 NC Not Connected<br />

13 NC Not Connected<br />

14 /ENABLE IN <strong>Bill</strong> Inhibit (Hi) / Accept (Lo) Signal Lo<br />

15 NC Not Connected<br />

16 /BUSY OUT <strong>Acceptor</strong> Operating Signal Lo<br />

17 /ABN OUT <strong>Acceptor</strong> Error Signal Lo<br />

18 /FULL OUT Cash Box Full signal Lo<br />

*1 I/O (input/output) is the term from bill acceptor’s side.<br />

•DBV-301<br />

Pin No. Signal Name I/O *1 Function Active<br />

1 VDD1 DC24V<br />

2 VSS1 DC24V GND<br />

3 NC Not Connected<br />

4 NC Not Connected<br />

5 NC Not Connected<br />

6 NC Not Connected<br />

7 NC Not Connected<br />

8 NC Not Connected<br />

9 NC Not Connected<br />

10 SG Signal Ground<br />

11 /VEND OUT Accepted denomination Signal Lo<br />

12 NC Not Connected<br />

13 NC Not Connected<br />

14 /ENABLE IN <strong>Bill</strong> Inhibit (Hi) / Accept (Lo) Signal Lo<br />

15 NC Not Connected<br />

16 /BUSY OUT <strong>Acceptor</strong> Operating Signal Lo<br />

17 /ABN OUT <strong>Acceptor</strong> Error Signal Lo<br />

18 /FULL OUT Cash Box Full signal Lo<br />

*1 I/O (input/output) is the term from bill acceptor’s side.<br />