CHAPTER 4 Trouble Shooting and Diagnostics<br />

4-3-9. Stacker Motor Forward/Reverse Rotation Test<br />

This detects the Stacker Motor’s forward/reverse rotation condition. If the red, yellow and green<br />

LED lights, refer to Stacker Motor Forward/Reverse Rotation Error Code shown below and detects<br />

the error.<br />

1 2 3 4 5 6 7 8<br />

ON<br />

1 2 3 4 5 6 7 8<br />

ON<br />

Forward Rotation<br />

Reverse Rotation<br />

Stacker Motor Forward/Reverse Rotation Error Code<br />

Condition<br />

LED Motor Condition Causes and Solution<br />

R Y G<br />

1 1 1 Normal -<br />

2 2 2 Fast Contact JCM.<br />

3 3 3 Slow<br />

Power Supply Board failure may occurs. Refer to 3-1. How to<br />

Remove Circuit Board to change the Power Supply Board.<br />

6 6 6 Abnormal<br />

Motor encoder sensor does not detect. Check all harnesses and<br />

connectors. The CPU board failure may occur. Change the CPU<br />

board. Refer to Chapter 3. Disassembly Instructions.<br />

4 - 13