CHAPTER 4 Trouble Shooting and Diagnostics<br />
4-3-9. Stacker Motor Forward/Reverse Rotation Test<br />
This detects the Stacker Motor’s forward/reverse rotation condition. If the red, yellow and green<br />
LED lights, refer to Stacker Motor Forward/Reverse Rotation Error Code shown below and detects<br />
the error.<br />
1 2 3 4 5 6 7 8<br />
ON<br />
1 2 3 4 5 6 7 8<br />
ON<br />
Forward Rotation<br />
Reverse Rotation<br />
Stacker Motor Forward/Reverse Rotation Error Code<br />
Condition<br />
LED Motor Condition Causes and Solution<br />
R Y G<br />
1 1 1 Normal -<br />
2 2 2 Fast Contact JCM.<br />
3 3 3 Slow<br />
Power Supply Board failure may occurs. Refer to 3-1. How to<br />
Remove Circuit Board to change the Power Supply Board.<br />
6 6 6 Abnormal<br />
Motor encoder sensor does not detect. Check all harnesses and<br />
connectors. The CPU board failure may occur. Change the CPU<br />
board. Refer to Chapter 3. Disassembly Instructions.<br />
4 - 13