28.04.2015 Views

MC75 AT Command Set

MC75 AT Command Set

MC75 AT Command Set

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>MC75</strong> <strong>AT</strong> <strong>Command</strong> <strong>Set</strong><br />

7.22 <strong>AT</strong>^SLCC<br />

s<br />

7.22 <strong>AT</strong>^SLCC Siemens defined command to list current calls of ME<br />

<strong>AT</strong>^SLCC covers essentially the same information as GSM 07.07 command <strong>AT</strong>+CLCC, with the following additions:<br />

• The execute command response contains an additional parameter indicating<br />

whether the call has been assigned a traffic channel by the network (transmission of data or inband<br />

information is possible).<br />

• The additional write command allows to activate Event reporting for the list of current calls. If event reporting<br />

is active for an interface, a call status transition (cf. Call Status Information) and (if desired) the<br />

assignment of a traffic channel will generate an event report indication to this interface. In order to receive<br />

this event report as an URC, the URC presentation mode for this interface has to be configured with<br />

<strong>AT</strong>+CMER.<br />

The frequency of event report generation can be configured with <strong>AT</strong> command <strong>AT</strong>^SCFG. Refer to Call<br />

Status Information for further detail on the configuration options.<br />

• The additional read command allows to determine the event reporting mode which indicates whether the<br />

interface receives event report indications for the list of current calls. Mind that the URC will be displayed only<br />

if the URC presentation mode for the interface concerned has been configured with <strong>AT</strong>+CMER.<br />

Syntax<br />

Test <strong>Command</strong><br />

<strong>AT</strong>^SLCC=?<br />

Response(s)<br />

^SLCC: (list of supporteds)<br />

OK<br />

Read <strong>Command</strong><br />

<strong>AT</strong>^SLCC?<br />

Response(s)<br />

^SLCC: <br />

OK<br />

Exec <strong>Command</strong><br />

<strong>AT</strong>^SLCC<br />

Response(s)<br />

[^SLCC:, , , , , [, ,<br />

[, ]]]<br />

[^SLCC:, , , , , [, ,<br />

[, ]]]<br />

[^SLCC:...]<br />

OK<br />

ERROR<br />

+CME ERROR<br />

Write <strong>Command</strong><br />

<strong>AT</strong>^SLCC=[]<br />

Response(s)<br />

OK<br />

ERROR<br />

+CME ERROR: <br />

Reference(s) PIN ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge Last<br />

Siemens % % % % % % % ! ! !<br />

<strong>MC75</strong>_<strong>AT</strong>C_V01.001 Page 160 of 475 6/2/05<br />

Confidential / Released

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!