<strong>MC75</strong> <strong>AT</strong> <strong>Command</strong> <strong>Set</strong><br />

4. Serial Interface Control <strong>Command</strong>s s<br />

4. Serial Interface Control <strong>Command</strong>s<br />

The <strong>AT</strong> <strong>Command</strong>s described in this chapter allow the external application to determine various settings related<br />

to the <strong>MC75</strong>'s serial interface.<br />

4.1 <strong>AT</strong>\Q Flow control<br />

Syntax<br />

Exec <strong>Command</strong><br />

<strong>AT</strong>\Q[]<br />

Response(s)<br />

OK<br />

If RTS/CTS flow control is not supported by interface and is 2 or 3:<br />

ERROR<br />

Reference(s) PIN ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge Last<br />

SIEMENS ! % % ! § § § ! % !<br />

Parameter Description<br />

(num)(&W)(&V)<br />

[0] (&F) Disable flow control<br />

1 XON/XOFF software flow control<br />

2 Only CTS by DCE (TA)<br />

3 RTS/CTS hardware flow control<br />

Recommended for the following procedures: incoming or outgoing data calls,<br />

fax calls, MUX mode.<br />

Often, the initialization routine of Fax programs includes enabling RTS/CTS<br />

handshake, eliminating the need to issue <strong>AT</strong>\Q3 once again.<br />

Notes<br />

• When using XON/XOFF flow control (<strong>AT</strong>\Q1) in online mode, +++ should not be used while the data transmission<br />

is paused with XOFF. Before entering the command mode with +++ the paused transmission should<br />

be resumed using the XON character.<br />

• For compatibility reasons, the <strong>AT</strong>\Q command can be used in Multiplex mode, though the settings will not<br />

take effect. However, be aware that whenever you use the <strong>AT</strong>\Q write command in Multiplex mode and then<br />

save the current configuration to the user profile with <strong>AT</strong>&W, the changed <strong>AT</strong>\Q setting will become active after<br />

restart.<br />

• Flow control can also be set using <strong>AT</strong>+IFC.<br />

<strong>MC75</strong>_<strong>AT</strong>C_V01.001 Page 83 of 475 6/2/05<br />

Confidential / Released