<strong>MC75</strong> <strong>AT</strong> <strong>Command</strong> <strong>Set</strong><br />

11.10 <strong>AT</strong>+CGQMIN<br />

s<br />

11.10 <strong>AT</strong>+CGQMIN Quality of Service Profile (Minimum acceptable)<br />

Syntax<br />

Test <strong>Command</strong><br />

<strong>AT</strong>+CGQMIN=?<br />

Response(s)<br />

+CGQMIN: , (list of supported s), (list of supported s), (list of<br />

supported s), (list of supported s), (list of supported s)<br />

OK<br />

ERROR<br />

+CME ERROR<br />

Read <strong>Command</strong><br />

<strong>AT</strong>+CGQMIN?<br />

Response(s)<br />

[+CGQMIN: , , , , , ]<br />

[+CGQMIN: ...]<br />

OK<br />

ERROR<br />

+CME ERROR<br />

Write <strong>Command</strong><br />

<strong>AT</strong>+CGQMIN=[[, [, [, [, [, ]]]]]]<br />

Response(s)<br />

OK<br />

ERROR<br />

+CME ERROR<br />

Reference(s) PIN ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge Last<br />

GSM 07.07 % % % % % % % ! % !<br />

<strong>Command</strong> Description<br />

The test command returns values supported as a compound value. If the MT supports several PDP types, the<br />

parameter value ranges for each PDP type are returned on a separate line.<br />

The read command returns the current settings for each defined context.<br />

This command allows the TE to specify a minimum acceptable profile which is checked by the MT against the<br />

negotiated profile returned in the Activate PDP Context Accept message.<br />

The set command specifies a profile for the context identified by the (local) context identification parameter,<br />

.<br />

A special form of the set command, <strong>AT</strong>+CGQMIN= causes the minimum acceptable profile for context<br />

number to become undefined. In this case no check is made against the negotiated profile.<br />

<strong>AT</strong>&F and <strong>AT</strong>Z will undefine the minimum QoS profiles of every context which is not active or not online.<br />

Parameter Description<br />

(num)<br />

Parameter specifies a particular PDP context definition. The parameter is local to the TE-MT interface and is<br />

used in other PDP context-related commands.<br />

1...2<br />

<strong>MC75</strong>_<strong>AT</strong>C_V01.001 Page 283 of 475 6/2/05<br />