<strong>MC75</strong> <strong>AT</strong> <strong>Command</strong> <strong>Set</strong><br />

10.6 <strong>AT</strong>^SISW<br />

s<br />

10.6 <strong>AT</strong>^SISW Internet Service Write Data<br />

<strong>AT</strong>^SISW write command triggers writing data via the Internet service configured configured with <strong>AT</strong>^SISS.<br />

<strong>MC75</strong> returns the amount of data which can be written:<br />

• value equal 0 indicates that the <strong>MC75</strong> failed to enter online data mode. Details about<br />

the cause of failure is available using <strong>AT</strong>+CEER.<br />

• value greater than 0 indicates that the <strong>MC75</strong> switches into online data mode to transfer<br />

the given number of bytes.<br />

A URC "^SISW: , " will be issued if<br />

• the <strong>MC75</strong> is capable to send data after opening the Internet service or<br />

• less transmission buffer space was confirmed (in ) than requested (with ) or<br />

• or all available data have been transferred.<br />

This mechanism is designed to avoid polling for free transmission buffer space and thus, free the TA for other<br />

tasks.<br />

Syntax<br />

Test <strong>Command</strong><br />

<strong>AT</strong>^SISW=?<br />

Response(s)<br />

OK<br />

Write <strong>Command</strong><br />

<strong>AT</strong>^SISW=, <br />

Response(s)<br />

^SISW: , Number of data bytes are expected as specified by<br />

<br />

OK<br />

ERROR<br />

+CME ERROR: <br />

PIN ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge Last<br />

§ % % % % % % ! ! %<br />

Unsolicited Result Code<br />

^SISW: , <br />

Data availability status of the Internet service configured with <strong>AT</strong>^SISS has changed.<br />

Parameter Description<br />

(num)<br />

0 ... 9 specified with <strong>AT</strong>^SISS.<br />

(num)<br />

Requested number of data bytes to be transmitted via the Internet service configured with <strong>AT</strong>^SISS.<br />

1...1500<br />

(num)<br />

Confirmed number of data bytes to be transmitted via the Internet service configured in . This<br />

number may be less or equal to the value requested with . 0 value indicates that no data<br />

can be written.<br />

<strong>MC75</strong>_<strong>AT</strong>C_V01.001 Page 258 of 475 6/2/05<br />