<strong>MC75</strong> <strong>AT</strong> <strong>Command</strong> <strong>Set</strong><br />

13.28 <strong>AT</strong>^SSMSS<br />

s<br />

13.28 <strong>AT</strong>^SSMSS <strong>Set</strong> Short Message Storage Sequence<br />

The short message storage ''MT'' (see <strong>AT</strong>+CPMS) is a logical storage. It consists of two physical storages ''ME''<br />

and ''SM''. This command allows to select the sequence of addressing this storage.<br />

Syntax<br />

Test <strong>Command</strong><br />

<strong>AT</strong>^SSMSS=?<br />

Response(s)<br />

^SSMSS: (list of supported) s<br />

Read <strong>Command</strong><br />

<strong>AT</strong>^SSMSS?<br />

Response(s)<br />

^SSMSS: <br />

OK<br />

Write <strong>Command</strong><br />

<strong>AT</strong>^SSMSS=<br />

Response(s)<br />

OK<br />

Reference(s) PIN ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge Last<br />

SIEMENS ! % % % % % % ! % !<br />

Parameter Description<br />

(num)<br />

MT sequence<br />

0 (&F) ''MT'' storage is ''ME'' then ''SM<br />

1 ''MT'' storage is ''SM'' then ''ME''<br />

Note<br />

• Access to the SIM storage is faster. For compatibility with previous software re-leases, the ''MT'' sequence<br />

=0 is the factory default.<br />

<strong>MC75</strong>_<strong>AT</strong>C_V01.001 Page 356 of 475 6/2/05<br />