<strong>MC75</strong> <strong>AT</strong> <strong>Command</strong> <strong>Set</strong><br />

4.7 <strong>AT</strong>+IFC<br />

s<br />

4.7 <strong>AT</strong>+IFC <strong>Set</strong> Flow Control separately for data directions<br />

The command <strong>AT</strong>+IFC can be used to set or query the data flow control separately for each data direction. In<br />

contrast to this, flow control settings made with <strong>AT</strong>\Q are valid in both data directions.<br />

Syntax<br />

Test <strong>Command</strong><br />

<strong>AT</strong>+IFC=?<br />

Response(s)<br />

+IFC: (list of supported s), (list of supported s)<br />

OK<br />

Read <strong>Command</strong><br />

<strong>AT</strong>+IFC?<br />

Response(s)<br />

+IFC: , <br />

OK<br />

Write <strong>Command</strong><br />

<strong>AT</strong>+IFC=, <br />

Response(s)<br />

OK<br />

ERROR<br />

Reference(s) PIN ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge Last<br />

V.250 ! % % ! § § § ! % !<br />

Parameter Description<br />

(num)(&W)<br />

Specifies the method used by the TE when receiving data from the TA.<br />

[0] none<br />

1 XON/XOFF, terminate flow control in the Cellular Engine<br />

2 RTS line<br />

3 XON/XOFF, evaluate flow control in the Cellular Engine and pass it through<br />

(over the air) to the opposite TE<br />

(num)(&W)<br />

Specifies the method used by the TA when receiving data from the TE.<br />

[0] none<br />

1 XON/XOFF<br />

2 CTS line<br />

<strong>MC75</strong>_<strong>AT</strong>C_V01.001 Page 90 of 475 6/2/05<br />