Sustainable C<strong>on</strong>structi<strong>on</strong> and Design <str<strong>on</strong>g>2011</str<strong>on</strong>g><br />

V. Secti<strong>on</strong> after the moment of take off;<br />

VI. Take off process in the air.<br />

The examinati<strong>on</strong> of secti<strong>on</strong>s after these happened separately. We used Fourier transformati<strong>on</strong> (FFT)<br />

examining the secti<strong>on</strong>s. Is a results of FFT we got vibrati<strong>on</strong> accelerati<strong>on</strong>-frequency values from the<br />

vibrati<strong>on</strong> accelerati<strong>on</strong>-time functi<strong>on</strong>s [5].<br />

This guaranteed for us that we could determined the repetiti<strong>on</strong> member (frequency) of load bel<strong>on</strong>ging to the<br />

characteristic accelerati<strong>on</strong> values. An example pricked out of Fourier transformati<strong>on</strong> can be seen in Figure<br />

6. The characteristic accelerati<strong>on</strong> values are marked in the Figure so, as an exposed value (A), as well as a<br />

characteristic secti<strong>on</strong> (B).<br />

14<br />

12<br />

10<br />

8<br />

Vibrati<strong>on</strong>-accelerati<strong>on</strong> in „z” directi<strong>on</strong> measured in the cabin<br />

Belső z irányítottságú gyorsulás<br />

d<br />

I. II. III. IV. V. VI.<br />

a [gyorsulás] [m/s 2 ]<br />

6<br />

4<br />

2<br />

0<br />

0<br />

-2<br />

5 10 15 20 25 30<br />

-4<br />

-6<br />

-8<br />

Time, t [idő] [s] t [s]<br />

Figure 5. Characteristic secti<strong>on</strong>s of vibrati<strong>on</strong>-accelerati<strong>on</strong> in „z” directi<strong>on</strong> in the functi<strong>on</strong> of<br />

time measured in the cabin<br />

Vibrati<strong>on</strong>-accelerati<strong>on</strong>, Rezgésgyorsulás, a a [m/s 2 ]<br />

2 ] Rezgésgyorsulás, Vibrati<strong>on</strong>-accelerati<strong>on</strong>, a [m/s a 2 [m/s ]<br />

2 ]<br />

10<br />

0<br />

-10<br />

0 2 4 6 8 10<br />

Idő, t [s]<br />

1.5<br />

1<br />

0.5<br />

0<br />

0 5 10 15 20 25 30 35 40 45 50<br />

Frekvencia, f [Hz]<br />

Figure 6. Time-functi<strong>on</strong> of accelerati<strong>on</strong> measured in the aircraft and FFT frequency<br />

spectrum, in the secti<strong>on</strong> of decelerating taxiing <strong>on</strong> the field, „z” directi<strong>on</strong><br />

It can be stated by knowing the results that the breakdown of the silent-bloc then happens so<strong>on</strong>er if the<br />

load is accompanied with much higher repetiti<strong>on</strong> number.<br />

Knowing this it can be established that fact the critical secti<strong>on</strong>s c<strong>on</strong>sidering the silent-bloc are the<br />

decelerating/accelerating taxiing <strong>on</strong> the ground (III., IV. secti<strong>on</strong>) and not the moments of landing as well as<br />

take off. The characteristic values of accelerati<strong>on</strong> and frequency of decelerating/accelerating taxiing <strong>on</strong> the<br />

ground had to be applied for the further examinati<strong>on</strong>s.<br />